• Spine · Sep 2010

    Comparative Study

    Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures.

    • Vidyadhar V Upasani, Claire Robertson, Deborah Lee, Tucker Tomlinson, and Andrew T Mahar.
    • Department of Orthopaedic Surgery, University of California San Diego, and Orthopedic Biomechanics Research Center, Rady Children's Hospital and Health Center, San Diego, CA, USA.
    • Spine. 2010 Sep 1; 35 (19): 1783-8.

    Study DesignIn vitro biomechanical investigation.ObjectiveTo evaluate differences in biomechanical stability of vertebral compression fractures repaired using balloon kyphoplasty versus a titanium mesh implant.Summary Of Background DataVertebral compression fractures may be stabilized using an expandable balloon followed by cement injection. There are small but finite risks of endplate fracture and cement extravasation with this procedure. Alternative techniques may affect cement injection volumes, height maintenance, and biomechanical stability but require investigation.MethodsFour male human cadaveric spines from T2 to L5 were used in this study. After determining bone mineral density, individual vertebral bodies were dissected and inspected for previous fractures or additional exclusion criteria. In the remaining vertebral bodies (n=48) anterior wedge fractures were created using a materials testing machine. Fractured vertebral bodies were systematically randomized to be repaired either with balloon kyphoplasty or with titanium mesh implant and polymethylmethacrylate bone cement, using image intensified fluoroscopy. Anterior vertebral body height (cm) was measured initially, after mechanically creating an anterior wedge fracture, after repairing the compression fracture with either technique, and after recompressing the vertebral body following a 24-hour cement polymerization period. Data for cement injection volume (mL) and height maintained following testing (cm) were compared between repair groups using a 1-way analysis of variance (P<0.05). Data for stiffness (N/mm), yield load (N), and ultimate load (N) were compared between intact bodies and repaired bodies using a 2-way analysis of variance (P<0.05).ResultsThere was significantly less cement injected (P<0.001) and significantly greater height maintained (P<0.025) with the titanium implant group compared to the kyphoplasty group. There were no significant differences in biomechanical stability between the 2 groups (P>0.05).ConclusionThe titanium implant was biomechanically equivalent to the kyphoplasty repair while necessitating less cement and providing greater height maintenance in vitro. Improvements in pain and function could not be specifically addressed in this in vitro study and should be evaluated in a clinical case series.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.