• Jornal de pediatria · Jul 2005

    Comparative Study

    [Accuracy, utility and complications of continuous glucose monitoring system (CGMS) in pediatric patients with type 1 diabetes].

    • Frederico F R Maia and Levimar R Araújo.
    • Faculdade de Ciências Médicas de Minas Gerais (FCMMG), Belo Horizonte, MG, Brazil. fredfrm@hotmail.com
    • J Pediatr (Rio J). 2005 Jul 1; 81 (4): 293-7.

    ObjectiveTo evaluate the accuracy, utility and complications of continuous glucose monitoring system in children and adolescents with type 1 diabetes.MethodsThis retrospective study assessed 16 type 1 diabetic patients (16.12+/-4.41 years) submitted to continuous glucose monitoring system (Medtronic; Northridge, CA) for 72 hours. The following parameters were analyzed: mean capillary glucose level and mean glucose value measured by the continuous glucose monitoring system; glucose excursions (continuous glucose monitoring system vs. capillary glucose measurement), postprandial hyperglycemia (NR < 140 mg/dl), nocturnal hypoglycemia, complications (trauma, local infection, disconnection) and therapeutic management after continuous glucose monitoring. A1c levels were measured at the beginning and after 3 months of the study.ResultsThe mean capillary glucose values were 214.3+/-66.5 mg/dl vs. 207.6+/-54.6 mg/dl by continuous glucose monitoring system, with a significant correlation (p = 0.001). The correlation coefficient and mean absolute error were 0.86+/-0.21 and 12.6% of the median, respectively. The continuous glucose monitoring system was significantly more efficient in detecting glucose excursion than fingerstick capillary blood sampling (p = 0.04; W = 74), and postprandial hyperglycemia was identified in 60% of type 1 diabetic patients with a median value of 157 mg/dl (< 140 mg/dl). Nocturnal hypoglycemia was detected in 46.7% of these patients. The evaluation of A1c levels in eight (50%) patients before continuous glucose monitoring and after 3 months showed a significantly lower level of A1c in this population (8.18+/-1.5 vs. 7.28+/-1.3; p = 0.034). The therapeutic management of type 1 diabetes was changed in 100% of patients. No complications were detected in 93.7% of patients.ConclusionsThe continuous glucose monitoring system showed to be a very safe, well-tolerated and highly accurate method, with a low complication rate. It is a good method to identify glucose excursion and postprandial hyperglycemia, and to improve metabolic changes in therapeutic strategies, with a significant impact on the A1c levels of pediatric diabetic patients. The efficacy of the continuous glucose monitoring system in detecting hypoglycemia is still unclear in the medical literature.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…