• Interact Cardiovasc Thorac Surg · Jun 2015

    Review

    What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?

    • Christos Tourmousoglou, Vivek Rao, Spiros Lalos, and Dimitrios Dougenis.
    • University of Ioannina Medical School, Ioannina, Greece christostourmousoglou@hotmail.com.
    • Interact Cardiovasc Thorac Surg. 2015 Jun 1; 20 (6): 837-43.

    AbstractA best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether transcatheter aortic valve-in-valve replacement (viv-TAVR) or redo aortic valve replacement (rAVR) is the best strategy in a patient with a degenerative bioprosthetic aortic valve. Altogether, 162 papers were found using the reported search, of which 12 represented the best evidence to answer the question. The authors, journal, date, country of publication, patient group, study type, outcomes and results of papers are tabulated. The results of the studies provided interesting results. All the studies are retrospective. Four papers reported the results of redo aortic valve replacement in patients with failed aortic bioprosthetic valve, six papers demonstrated their results with transcatheter aortic valve-in-valve replacement for the same indication and two papers reported their propensity-matched analysis of outcomes between viv-TAVR and rAVR in patients with previous cardiac surgery. Thirty-day mortality for rAVR was 2.3-15.5% and 0-17% for viv-TAVR. For rAVR, survival rate at 30 days was 83.6%, 76.1% at 1 year, 70.8% at 3 years, at 51.3-66% at 5 years, 61% at 8 years and 61.5% at 10 years. For viv-TAVR, the overall Kaplan-Meier survival rate at 1 year was 83.2%. After viv-TAVR at 1 year, 86.2% of surviving patients were at New York Heart Association (NYHA) class I/II. The complications after rAVR were stroke (4.6-5.8%), reoperation for bleeding (6.9-9.7%), low-cardiac output syndrome (9.9%) whereas complications after viv-TAVR at 30 days were major stroke (1.7%), aortic regurgitation of at least moderate degree (25%), new permanent pacemaker implantation rate (0-11%), ostial coronary obstruction (2%), need for implantation of a second device (5.7%) and major vascular complications (9.2%). It is noteworthy to mention that there is a valve-in-valve application that provides information to surgeons for choosing the correct size of the TAVR valve. Transcatheter aortic valve-in-valve procedures are clinically effective, at least in the short term, and could be an acceptable approach in selected high-risk patients with degenerative bioprosthetic valves. Redo AVR achieves acceptable medium and long-term results. Both techniques could be seen as complementary approaches for high-risk patients.© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…