- Y Pouzeratte, M Sebbane, B Jung, J-M Delay, J Eliet, J-J Eledjam, X Capdevila, and S Jaber.
- Hôpital Saint-Eloi, Department of Anesthesia, CHU Montpellier, Montpellier, France.
- Eur J Anaesthesiol. 2008 Aug 1; 25 (8): 634-41.
Background And ObjectivesUnlike for intensive care unit and home mechanical ventilators, no study has evaluated the user-friendliness of the recently introduced new anaesthesia workstations.MethodsWe performed a prospective study to evaluate the user-friendliness of four anaesthesia workstations, which were categorized into two groups: first-generation (Kion) and second-generation (Avance, Felix and Primus). Twenty users (12 nurse-anaesthetists and 8 anaesthesiologists) from three different anaesthesia departments at the same univeristy hospital participated in the study. The user-friendliness scale evaluated 10 criteria, including two design and monitoring criteria, four maintenance criteria and four ventilation use criteria. Each criterion was evaluated from 0 (poor) to 10 (excellent).ResultsThe mean score obtained for the first-generation workstation was lower than those obtained for the three second-generation workstations (P < 0.05). No significant differences in the overall user-friendliness score was observed for the three second-generation workstations. The first-generation workstation obtained a significantly lower score than the three second-generation workstations for the design criteria (P < 0.01). For the screen criteria, the highest score was obtained by Felix, which has the largest screen and associated characters. For the main maintenance criteria, Kion and Felix obtained the lowest scores. No significant differences between the four anaesthesia workstations were found for only three of the user-friendliness criteria (self-test, alarms and settings).ConclusionsAnaesthesia machines have benefited from considerable advances in design and technology. This novel user-friendliness scale revealed that the most recent workstations were more appreciated by users than the first-generation of anaesthesia workstations. This user-friendliness scale may help the anaesthetic staff to 'consensually' choose the future workstation for their anaesthesia department.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.