• World Neurosurg · Aug 2017

    Case Reports Comparative Study

    Overlapped Stenting Combined with Coiling for Blood Blister-like Aneurysms: Comparison of Low-profile Visualized Intraluminal Support (LVIS) Stent and Non-LVIS Stent.

    • Deyuan Zhu, Yibin Fang, Pengfei Yang, Ping Zhang, Lei Chen, Yi Xu, Bo Hong, Qinghai Huang, and Jian-Min Liu.
    • Department of Neurosurgery, Changhai Hospital, Second Military Medical University, Shanghai, China.
    • World Neurosurg. 2017 Aug 1; 104: 729-735.

    ObjectiveTo evaluate the safety and efficacy of overlapped stenting for blood blister-like aneurysms (BBAs) and to compare the outcomes between Low-profile Visualized Intraluminal Support (LVIS) and non-LVIS stents.MethodsA retrospective review of the aneurysm database identified 37 patients with intracranial carotid artery BBAs treated by overlapped stenting in our institution from June 2013 to June 2016. The clinical characteristics and angiographic results were reviewed.ResultsOverlapped stenting combined with coiling were applied in 37 BBAs, including LVIS stents in 18 cases and non-LVIS stents in 19. For the LVIS group, angiographic results at 3-24 months were complete occlusion in 15 cases (83.3%), improved in 2 cases (11.1%), and recanalized in 1 case (5.6%). The modified Rankin Scale scores at 3-36 months' follow-up were 0-2 in 15 cases (83.3%) and 3-6 in 3 cases (16.7%). For the non-LVIS group, angiographic results at 3-46 months were complete occlusion in 12 cases (63.2%) and recanalized in 7 cases (36.8%). Clinical outcomes at 6-58 months were modified Rankin Scale scores of 0-2 in 17 cases (89.5%) and 3-6 in 2 cases (10.5%). Use of the LVIS stent was less likely to result in recanalization (odds ratio 0.10, 95% confidence interval 0.01-0.93, P = 0.042) than the non-LVIS stent. The LVIS group had a lower average number of stents than did the non-LVIS group (2.2 vs. 2.6, P = 0.016). In terms of complication rate (11.1% vs. 5.3%, P = 0.604), good outcome rate (83.3% vs. 89.5%, P = 0.660), and immediate angiographic result (P = 0.424), no statistically significant difference between the 2 groups was found.ConclusionsOverlapped LVIS stenting combined with coiling is feasible and safe for BBAs. Overall, the LVIS stent provided less risk of BBA recurrence compared with the non-LVIS stent and did not increase the risk of procedure-related complications.Copyright © 2017 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…