-
Review Meta Analysis Comparative Study
Effects of different fresh gas flows with or without a heat and moisture exchanger on inhaled gas humidity in adults undergoing general anaesthesia: A systematic review and meta-analysis of randomised controlled trials.
- Braz José R C JRC From the Department of Anaesthesiology (JRCB, MGB, YH, LGB, RED), Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery (RHGM), Bot, Mariana G Braz, Yoko Hayashi, Martins Regina H G RHG, Marluci Betini, Leandro G Braz, and Regina El Dib.
- From the Department of Anaesthesiology (JRCB, MGB, YH, LGB, RED), Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery (RHGM), Botucatu Medical School, UNESP-Universidade Estadual Paulista, Botucatu, São Paulo, Brazil, and Technical Division of Library and Documentation (MB), UNESP-Universidade Estadual Paulista, Botucatu, São Paulo, Brazil.
- Eur J Anaesthesiol. 2017 Aug 1; 34 (8): 515-525.
BackgroundThe minimum inhaled gas absolute humidity level is 20 mgH2O l for short-duration use in general anaesthesia and 30 mgH2O l for long-duration use in intensive care to avoid respiratory tract dehydration.ObjectiveThe aim is to compare the effects of different fresh gas flows (FGFs) through a circle rebreathing system with or without a heat and moisture exchanger (HME) on inhaled gas absolute humidity in adults undergoing general anaesthesia.DesignSystematic review and meta-analyses of randomised controlled trials. We defined FGF (l min) as minimal (0.25 to 0.5), low (0.6 to 1.0) or high (≥2). We extracted the inhaled gas absolute humidity data at 60 and 120 min after connection of the patient to the breathing circuit. The effect size is expressed as the mean differences and corresponding 95% confidence intervals (CI).Data SourcesPubMed, EMBASE, SciELO, LILACS and CENTRAL until January 2017.ResultsWe included 10 studies. The inhaled gas absolute humidity was higher with minimal flow compared with low flow at 120 min [mean differences 2.51 (95%CI: 0.32 to 4.70); P = 0.02] but not at 60 min [mean differences 2.95 (95%CI: -0.95 to 6.84); P = 0.14], and higher with low flow compared with high flow at 120 min [mean differences 7.19 (95%CI: 4.53 to 9.86); P < 0.001]. An inhaled gas absolute humidity minimum of 20 mgH2O l was attained with minimal flow at all times but not with low or high flows. An HME increased the inhaled gas absolute humidity: with minimal flow at 120 min [mean differences 8.49 (95%CI: 1.15 to 15.84); P = 0.02]; with low flow at 60 min [mean differences 9.87 (95%CI: 3.18 to 16.57); P = 0.04] and 120 min [mean differences 7.19 (95%CI: 3.29 to 11.10); P = 0.003]; and with high flow of 2 l min at 60 min [mean differences 6.46 (95%CI: 4.05 to 8.86); P < 0.001] and of 3 l min at 120 min [mean differences 12.18 (95%CI: 6.89 to 17.47); P < 0.001]. The inhaled gas absolute humidity data attained or were near 30 mgH2O l when an HME was used at all FGFs and times.ConclusionAll intubated patients should receive a HME with low or high flows. With minimal flow, a HME adds cost and is not needed to achieve an appropriate inhaled gas absolute humidity.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.