-
- Michael Kreinest, Dorothee Schmahl, Paul A Grützner, and Stefan Matschke.
- *Department of Trauma Surgery and Orthopedic Surgery, BG Trauma Centre Ludwigshafen, Ludwigshafen, Germany†Department of Anaesthesiology, Heidelberg University Hospital, Heidelberg, Germany.
- Spine. 2017 Apr 15; 42 (8): E482-E489.
Study DesignA prospective monocentric study.ObjectiveThe aim of the current study was the analysis of patient outcome and radiological results 3 years after implantation of a hydraulic expandable vertebral body replacement (VBR) system.Summary Of Background DataAround 70% to 90% of all traumatic spinal fractures are located in the thoracic and lumbar spine. Dorso-ventral stabilization is a frequently used procedure in traumatic vertebral body fracture treatment. VBR systems can be used to bridge bony defects. In the current study, a new VBR expanded by water pressure with adjustable endplates is used.MethodsAll patients who suffered a singular traumatic fracture to a thoracic or lumbar vertebral body (Th 5-L 5) in the period from November 2009 to December 2010 and (i) underwent dorsal instrumentation and (ii) afterwards received the implantation of a hydraulic VBR were included in this study. The clinical outcome (visual analogue scale [VAS] spine score, questionnaire) and radiological findings (sagittal angle, implant subsidence, and implant position) 3 years after implantation were analyzed.ResultsThe follow-up was successful for n = 47 patients (follow-up rate: 89%). Most of the patients (n = 40) were "generally/very satisfied" with their outcome. The mean rating of the VAS spine score was 65.2 ± 23.1 (range: 20.5-100.0). The analysis of the radiological data showed an average subsidence of the implants of 1.1 ± 1.2 mm (range 0.0-5.0 mm). After the initial operation, the local sagittal angle remained stable in the follow-up 3 years later both for the thoracic spine and lumbar spine. Furthermore, no change in the implant's position was observed.ConclusionThe implantation of a hydraulically expandable VBR allows a permanent stable fixation after traumatic fractures of the thoracic and lumbar spine.Level Of Evidence2.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.