-
- Mehmet Eroglu, Gokhan Demirkiran, Ismail Aykut Kocyigit, Hasan Bilgili, Mehmet Burak Kaynar, Ali Bumin, Sadan Ozcan, and Muharrem Yazici.
- *Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Turkey†Department of Surgery, Ankara University Faculty of Veterinary Medicine, Ankara, Turkey‡Department of Physics Engineering, Hacettepe University, Ankara, Turkey.
- Spine. 2017 May 1; 42 (9): E504-E508.
Study DesignExperimental animal study.ObjectiveTo investigate the interaction between magnetically controlled growing rods (MCGRs) and magnetic resonance imaging (MRI).Summary Of Background DataGrowing rod treatment through serial operations results in adverse effects on the patient and high treatment costs. MCGRs can be lengthened noninvasively in an outpatient setting and with lower treatment costs. When MRI investigation is required, the interaction between MCGRs and MRI is an issue of concern in patients with MCGRs. This study investigated MRI compatibility of MCGRs in an in vivo setting.MethodsThe study was conducted on three sheep. A standard posterior approach was used. One polyaxial pedicle screw at the ends was placed. Two sheep were instrumented unilaterally and one bilaterally with MCGRs. Temperature change was measured using MR-compatible sensors. Thoracic and lumbar MRIs were obtained using a 0.3 T MRI unit. MRI waves were applied for 45 minutes and temperature changes were recorded every 3 minutes. The lengths of the MCGRs were measured and anteroposterior and lateral spine radiographs were obtained pre- and postoperatively.ResultsNo displacement in the positions of the MCGRs occurred. The lengths of the MCGRs did not change compared with the preoperative length. The ability of the MCGRs to elongate was not impaired after MRI scanning. There was a mean increase in the temperature of the MCGRs by 1.45°C (0.5-2.4°C). The MCGRs had a strong scattering effect on MRI of the related segments.ConclusionThis study indicated that lower magnet MRI is safe in an animal model with MCGRs, with no displacement of the rods and no changes in their length, no significant heating, and no adverse effects on the lengthening mechanism but with a significant scattering effect on visualization of the surrounding tissues. Further investigations are needed to clarify the exact distance where an MRI investigation of distant organs may be done without scattering.Level Of EvidenceN/A.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.