Nihon Kyobu Geka Gakkai Zasshi · Aug 1997
[Three-dimensional transesophageal echocardiographic assessment for prosthetic valves].
- A Sezai, M Shiono, Y Orime, H Hata, S Yagi, S Tsukamoto, K Nakata, M Hasegawa, Y Sezai, and N Tanigawa.
- Second Department of Surgery, Nihon University School of Medicine, Tokyo, Japan.
- Nihon Kyobu Geka Gakkai Zasshi. 1997 Aug 1; 45 (8): 1084-9.
AbstractWe evaluated three-dimensional transesophageal echocardiographic assessment of the implanted mechanical valves by rotational scanning method. Patients were 7 mitral valve replacement and one aortic valve replacement, 2 mitral and aortic valve replacement. In 2 cases of 7 mitral valve replacement, the prosthetic valve regurgitation was evaluated using by color Doppler echocardiography. In this study, multiplane transesophageal probe was used. It rotated at 2-degree intervals from 0 to 180 degrees and the three-dimensional reconstruction was performed by echo scan workstation system (TOMTEC Inc, Munich, Germany). In mitral valve replacement cases, the valve motion of bileaflet valve (St. Jude Medical valve and ATS valve) were showed very clearly. The struts was easily recognized in the St. Jude Medical valve (SJM valve) cases. In one of SJM valve cases, the pannus formation was revealed, but it did not disturb valve motion. The prosthetic valve regurgitation can be seen accurately. However, aortic valve and ball valve cases cannot be reconstructed because of artifact from prosthetic valve and ultrasonic direction. The prosthetic valve regurgitation, pannus formation which was difficult to be showed in two-dimensional echocardiography and relationship between annulus and sewing cuff can be evaluated by this three-dimensional echocardiography. In this study, this system has some problems, for example real-time evaluation is impossible, aortic valve and ball valve cases cannot be reconstructed. However, we think that this new technology is suitable for evaluating valve thrombus, valve dysfunction and paravalvular leakage. In conclusion, the three-dimensional echo-cardiography demonstrated, reliable and accurate examination, and it can evaluate various complications of prosthetic valve.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.