• J Clin Monit Comput · Apr 2018

    Comparative Study Observational Study

    Four-wavelength near-infrared peripheral oximetry in cardiac surgery patients: a comparison between EQUANOX and O3.

    • Arnaud Ferraris, Matthias Jacquet-Lagrèze, and Jean-Luc Fellahi.
    • Service d'Anesthésie-Réanimation, Hôpital Cardiovasculaire et Pneumologique Louis Pradel, Hospices Civils de Lyon, 59 Boulevard Pinel, 69394, Lyon Cedex, France. arnaud.ferraris@chu-lyon.fr.
    • J Clin Monit Comput. 2018 Apr 1; 32 (2): 253-259.

    AbstractNear-infrared spectroscopy (NIRS) is a continuous and noninvasive technology that measures regional tissue oxygen saturation (rSO2). A new 4-wavelength generation of NIRS monitors is now available. We aimed to compare peripheral somatic rSO2 values given by the 4-wavelength EQUANOX™ 7600 device (Nonin Medical Inc., Plymouth, Mn) and O3™ device (Masimo Corporation, Irvine, CA). Twenty adult patients scheduled for conventional elective cardiac surgery with cardiopulmonary bypass over a 4-month period were included after local Ethics Committee approval. For each patient, 2 NIRS sensors (EQUANOX and O3) were placed over the medial part of the forearm. Thirteen couples of measurements were performed at predefined intraoperative time points. We compared 260 couples of absolute intraoperative rSO2 values. No significant difference was found between both monitors: EQUANOX median rSO2 60% (95% CI 57-62) versus O3 median rSO2 62% (95% CI 61-64), P = 0.103. Bias was 4.0% and limits of agreement were ±26.3%. Significant correlations were evidenced between EQUANOX and O3 rSO2 absolute values: rho = 0.758 (95% CI 0.701-0.806), P < 0.0001, and rSO2 percent maximum difference versus baseline: rho = 0.582 (95% CI 0.188-0.815), P = 0.007. While absolute values of rSO2 given by both devices were equivalent and well correlated, the clinical agreement is probably not acceptable, meaning that EQUANOX and O3 are not interchangeable in routine practice.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.