• Prehosp Emerg Care · Sep 2017

    Observational Study

    Advanced Airway Type and Its Association with Chest Compression Interruptions During Out-of-Hospital Cardiac Arrest Resuscitation Attempts.

    • Angela F Jarman, Christy L Hopkins, J Nicholas Hansen, Jonathan R Brown, Christopher Burk, and Scott T Youngquist.
    • Prehosp Emerg Care. 2017 Sep 1; 21 (5): 628-635.

    ObjectiveTo assess interruptions in chest compressions associated with advanced airway placement during cardiopulmonary resuscitation (CPR) of out-of-hospital cardiac arrest (OHCA) victims.MethodsThe method used was observational analysis of prospectively collected clinical and defibrillator data from 339 adult OHCA victims, excluding victims with <5 minutes of CPR. Interruptions in CPR, summarized by chest compression fraction (CCF), longest pause, and the number of pauses greater than 10 seconds, were compared between patients receiving bag valve mask (BVM), supraglottic airway (SGA), endotracheal intubation (ETI) via direct laryngoscopy (DL), and ETI via video laryngoscopy (VL). Secondary outcomes included first pass success and the effect of multiple airway attempts on CPR interruptions.ResultsDuring the study period, paramedics managed 23 cases with BVM, 43 cases with SGA, 148 with DL, and 125 with VL. There were no statistically significant differences between the airway groups with regard to longest compression pause (BVM 18 sec [IQR 11-33], SGA 29 sec [IQR 15-65], DL 26 sec [IQR 12-59], VL 22 sec [IQR 14-41]), median number of pauses greater than 10 seconds (BVM 2 [IQR 1-3], SGA 2 [IQR 1-3], DL 2 [IQR 1-4], VL 2 [IQR 1-3]), or CCF (0.92 for all groups). However, each additional attempt following failed initial DL was associated with an increase in the risk of additional chest compression pauses (relative risk 1.29, 95% confidence interval 1.02-1.64). Such an association was not observed with additional attempts using VL or SGA. First pass success was highest with SGA (77%), followed by between DL (68%) and VL (67%); these differences were not statistically significant.ConclusionsWhile summary measures of chest compression delivery did not differ significantly between airway classes in this observational study, repeated attempts following failed initial DL during cardiopulmonary resuscitation were associated with an increase in the number of pauses in chest compression delivery observed.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…