The base excess gap is not a valid tool for the quantification of unmeasured ions in cardiac surgical patients: A retrospective observational study.
- Michalis Agrafiotis, Maria Sileli, Fotini Ampatzidou, Ilias Keklikoglou, and Panagiotis Panousis.
- From the Second Department of Intensive Care Medicine, 'Georgios Papanikolaou' General Hospital of Thessaloniki, Thessaloniki, Greece.
- Eur J Anaesthesiol. 2013 Nov 1;30(11):678-84.
BackgroundThe base excess gap (BE(gap)) method is commonly used for the quantification of unmeasured ions in critically ill patients. However, it has never been validated against the standard quantitative acid-base approach.ObjectiveTo compare the BE(gap) as a tool for the prediction of the excess of unmeasured ions with the offset of strong ion gap (SIG) from its reference value.DesignA retrospective observational study.SettingAdult ICU in a tertiary hospital.PatientsOne hundred and thirty-five cardiac surgical patients admitted for postoperative care.InterventionsNone.Main Outcome MeasuresBE(gap) was calculated as BE(gap) = SBE - BE(si) - BE(wa), where SBE is the standard base excess, BE(si) is the partition due to strong ions ([Na+]-[Cl-]-[lactate-] - 30.5) and BE(wa) is the partition due to weak acids [0.25×{42 - (albumin)}]. The deviation of the observed SIG (SIG(ob)) from its reference value was calculated as deltaSIG = 2.85 - SIG(ob). We used Bland-Altman and concordance correlation analysis to compare BE(gap) with deltaSIG. A bias of ±1 meq l(-1) with limits of agreement of ±2 meq l(-1) and a concordant correlation coefficient of more than 0.9 were considered to indicate a strong agreement.ResultsThe concordant correlation coefficient between BE(gap) and deltaSIG was 0.702. The mean bias between the two variables was 1.8 meq l(-1), with a lower limit of agreement of -0.9 meq l(-1) and an upper limit of agreement of 4.4 meq l(-1).ConclusionThe BE gap method cannot reliably quantify the unmeasured ion excess in cardiac surgical patients. Clinicians should use the full Stewart-Figge model for quantitative acid-base assessments.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.