    Pipeline Embolization Device in treatment of 50 unruptured large and giant aneurysms.

    • Nimer Adeeb, Christoph J Griessenauer, Hussain Shallwani, Hakeem Shakir, Paul M Foreman, Justin M Moore, Adam A Dmytriw, Raghav Gupta, Adnan H Siddiqui, Elad I Levy, Kenneth Snyder, Mark R Harrigan, Christopher S Ogilvy, and Ajith J Thomas.
    • Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
    • World Neurosurg. 2017 Sep 1; 105: 232-237.

    IntroductionTreatment of large (≥20 mm) and giant (≥25 mm) intracranial aneurysms is challenging and can be associated with a high rate of morbidity and mortality. The Pipeline Embolization Device (PED) has been used effectively for the treatment of intracranial aneurysms achieving a high rate of complete occlusion. However, its safety and efficacy in treatment of large and giant aneurysms has not been evaluated fully.MethodsA retrospective analysis of consecutive aneurysms treated with PED between 2009 and 2016 at 3 academic institutions within the United States was performed. Large (≥20 mm) and giant aneurysms (≥25 mm) were selected for evaluation of occlusion and complication rates following treatment with PED.ResultsA total of 50 large and giant aneurysms were individually treated using PED. Aneurysms were fusiform (74%) or saccular (26%) in morphology. PED alone was used for treating 78% of the aneurysms, whereas PED with adjunctive coiling was used for treating 22%. The median length of angiographic follow-up was 13 months (mean follow up 20.4 months). At last follow-up, complete or near-complete occlusion (90-100%) was achieved in 76.9% of aneurysms. Symptomatic thromboembolic complications were encountered in 12% of procedures and symptomatic hemorrhagic complications in 8%.ConclusionsThe use of PED for the treatment of large and giant intracranial aneurysms is associated with good occlusion rates, but also a greater complication rate compared to aneurysms of smaller size. There was no significant difference in occlusion rate based on aneurysm shape or size, number of PEDs placed, or adjunctive coiling.Copyright © 2017 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…