• J Clin Monit Comput · Aug 2018

    Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device.

    • Igor Karnjuš, Dušan Mekiš, and Miljenko Križmarić.
    • Department of Nursing, Faculty of Health Sciences, University of Primorska, Polje 42, 6310, Izola, Slovenia. igor.karnjus@fvz.upr.si.
    • J Clin Monit Comput. 2018 Aug 1; 32 (4): 629-638.

    AbstractDuring patient sedation with liquid volatile anaesthetic, some problems may occur through a process called auto-pumping, defined as an expansion of bubbles inside the syringe, which can lead to uncontrolled anaesthetic delivery. The study examined how the temperature of liquid volatile anaesthetics (sevoflurane and isoflurane) and the presence of gas bubbles in the syringe affect the occurrence of auto-pumping when using the anaesthetic conserving device (ACD, AnaConDa™, Sedana Medical, Uppsala, Sweden). Four different circumstances for each volatile anaesthetic were tested with a bench study: volatile anaesthetic at room temperature or precooled with and without the presence of gas bubbles in the syringe. Liquid volatile anaesthetic was infused into the ACD via a syringe pump at a fixed rate and heated gradually until the temperature of the syringe surface reached 50 °C. A main-stream gas monitor was used to measure the expired fraction of volatile anaesthetic (FE vol%). The occurrence of auto-pumping was observed only in the subgroups containing gas bubbles, with both anaesthetics. In these subgroups, the values of the expired anaesthetic gas fraction increased dramatically with the expansion of gas bubbles in the syringe (ΔFE ranged from +1.6 to 2.4 vol% for sevoflurane and +2.3 to 3.4 vol% for isoflurane). Furthermore, when the heat source was removed, a substantial decline in anaesthetic agent values below the baseline was observed with both anaesthetics. The presence of gas bubbles in the syringe, especially when exposed to a heat source, may provoke auto-pumping with uncontrolled excessive anaesthetic delivery. If auto-pumping is suspected, the syringe pump must be stopped and the ACD removed from the breathing circuit at once.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…