• J Neurol Surg A Cent Eur Neurosurg · Mar 2015

    Evaluation of sciatic nerve function after ultrasonic and electrocautery muscle dissection: an electromyographic study.

    • Katsumasa Tanimoto, Basma Khoury, Ke Feng, and John M Cavanaugh.
    • Department of Biomedical Engineering, Wayne State University, Detroit, Michigan, United States.
    • J Neurol Surg A Cent Eur Neurosurg. 2015 Mar 1; 76 (2): 93-8.

    BackgroundMinimally invasive surgery has been developed with various innovative surgical tools. Ultrasonic (US) blades have been introduced as an alternative to conventional electrocautery (EC) monopolar device. The purpose of the present study was to evaluate the effects of surgical devices used for muscle dissection close to peripheral nerves on motor nerve function using electromyographic (EMG) recordings.Materials And MethodsA total of 24 rats were used in this study. The rats were assigned to the following three groups: Control (n = 8), EC (n = 8), and US (n = 8). A stimulus electrode was placed under the sciatic nerve at a sciatic notch. A pair of recording electrodes was implanted into the midbelly regions of the gastrocnemius muscle. To evoke compound muscle action potentials (CMAPs), 3-V stimuli with 0.3-ms duration were applied to the sciatic nerve at a frequency of 1 Hz. After the recording of the baseline, a monopolar surgical device (EC or US) was applied to cut the muscle 10 mm in length and 2 mm away on both sides of the sciatic nerve. Amplitude and latency of the evoked CMAPs were measured. CMAPs were monitored until 3 hours after the device application.ResultsThe EC device caused a marked drop in the amplitude of CMAP with no recovery at the end of the experiment. In the US group, the amplitude of CMAP was stable and constant CMAP over 3 hours, similar to the control group could be measured. In all three groups, the latency of CMAP showed no significant changes through the experiment.ConclusionThe study showed that the EC device resulted in injury to several motor units in the sciatic nerve. The US device may be a safe tool for muscle dissection around peripheral nerves.Georg Thieme Verlag KG Stuttgart · New York.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.