    BackgroundOrthotopic liver transplantation (OLT) is characterized by significant intraoperative hemodynamic variability. Accurate and real-time cardiac output (CO) monitoring aids clinical decision making during OLT. The purpose of this study is to compare accuracy, precision, and trending ability of CO estimation obtained noninvasively using pulse wave transit time (estimated continuous cardiac output [esCCO; Nihon Kohden, Tokyo, Japan]) or thoracic bioimpedance (ICON; Osypka Medical GmbH, Berlin, Germany) to thermodilution cardiac output (TDCO) measured with a pulmonary artery catheter.MethodsNineteen patients undergoing OLT were enrolled. CO measurements were collected with esCCO, ICON, and thermodilution at 5 time points: (T1) pulmonary artery catheter insertion; (T2) surgical incision; (T3) portal reperfusion; (T4) hepatic arterial reperfusion; and (T5) abdominal closure. The results were analyzed with Bland-Altman plot, percentage error (the percentage of the difference between the CO estimated with the noninvasive monitoring device and CO measured with the thermodilution technique), 4-quadrant plot with concordance rate (the percentage of the total number of points in the I and III quadrant of the 4-quadrant plot), and concordance correlation coefficient (a measure of how well the pairs of observations deviate from the 45-degree line of perfect agreement).ResultsAlthough TDCO increased at T3-T5, both esCCO and ICON failed to track the changes of CO with sufficient accuracy and precision. The mean bias of esCCO and ICON compared to TDCO were -2.0 L/min (SD, ±2.7 L/min) and -3.3 L/min (SD, ±2.8 L/min), respectively. The percentage error was 69% for esCCO and 77% for ICON. The concordance correlation coefficient was 0.653 (95% confidence interval [CI], 0.283-0.853) for esCCO and 0.310 (95% CI, -0.167 to 0.669) for ICON. Nonetheless, esCCO and ICON exhibited reasonable trending ability of TDCO (concordance rate: 95% [95% CI, 88-100] and 100% [95% CI, 93-100]), respectively. The mean bias was correlated with systemic vascular resistance (SVR) and arterial elastance (Ea) for esCCO (SVR, r = 0.610, 95% CI, 0.216-0.833, P < .0001; Ea, r = 0.692, 95% CI, 0.347-0.872; P < .0001) and ICON (SVR, r = 0.573, 95% CI, 0.161-0.815, P < .0001; Ea, r = 0.612, 95% CI, 0.219-0.834, P < .0001).ConclusionsThe noninvasive CO estimation with esCCO and ICON exhibited limited accuracy and precision, despite with reasonable trending ability, when compared to TDCO, during OLT. The inaccuracy of esCCO and ICON is especially large when SVR and Ea were decreased during the neohepatic phase. Further refinement of the technology is desirable before noninvasive techniques can replace TDCO during OLT.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.