• Paediatric anaesthesia · Aug 2017

    Introduction of color-flow injection test to confirm intravascular location of peripherally placed intravenous catheters.

    • Nischal K Gautam, Kayla R Bober, and Chunyan Cai.
    • Department of Anesthesiology, The University of Texas Medical School, Houston, TX, USA.
    • Paediatr Anaesth. 2017 Aug 1; 27 (8): 821-826.

    BackgroundThe incidence of infiltration and extravasation when using peripheral intravenous catheters is high in pediatric patients. Due to the lack of a gold standard test to confirm intravascular location of a peripherally placed intravenous catheter, we introduce a novel method, the color-flow injection test to assess the intravascular location of these catheters. For the color-flow injection test, 1 mL of normal saline was injected within 2 seconds in the distal intravenous catheter and changes in color-flow via ultrasonography were observed at the proximal draining veins. The primary objective of the study was to demonstrate feasibility of the color-flow injection test.MethodsA prospective study was conducted on children <18 years old undergoing general anesthesia. All peripheral intravenous catheters were subject to the color-flow injection test and standard confirmation tests.ResultsOut of the 100 patients enrolled, 22 patients came to the operating room with preexisting peripheral intravenous catheters. Intraoperatively, 105 attempts were made on 78 patients of which 27 catheters were considered as infiltrated during their placement. A final set of 100 catheters were considered for intraoperative usage after they had passed at least one of the standard confirmatory tests. For the color-flow injection test, the ideal sites for ultrasound evaluation of proximal draining veins were the axillary veins and femoral veins. The color-flow injection test was positive in 93 of the 100 catheters with color-flow changes noticed in the proximal veins during the saline injection. Of the 100 catheters, infiltration around seven catheter sites were observed within 2 hours of intraoperative usage and the color-flow injection test was negative in these seven catheters. The color-flow injection test was also negative in the 27 catheters that had infiltrated during their placement. The color-flow injection test was sensitive at 100% [95% confidence interval (CI)=95-100] and specific at 100% (95% CI=56-100) to indicate intravascular location.ConclusionWe were able to confirm intravascular location of peripheral intravenous catheters using the color-flow injection test in pediatric patients. The test can lead to early recognition of malfunctioning peripheral intravenous catheters and decrease rate of infiltration-extravasation injuries associated with their use.© 2017 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…