• Neurosurgery · Jan 2018

    Use of Stereovision for Intraoperative Coregistration of a Spinal Surgical Field: A Human Feasibility Study.

    • S Scott Lollis, Xiaoyao Fan, Linton Evans, Jonathan D Olson, Keith D Paulsen, David W Roberts, Sohail K Mirza, and Songbai Ji.
    • Division of Neurosurgery, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire.
    • Neurosurgery. 2018 Jan 1; 14 (1): 29-35.

    BackgroundThe use of image guidance during spinal surgery has been limited by several anatomic factors such as intervertebral segment motion and ineffective spine immobilization. In its current form, the surgical field is coregistered with a preoperative computed tomography (CT), often obtained in a different spinal confirmation, or with intraoperative cross-sectional imaging. Stereovision offers an alternative method of registration.ObjectiveTo demonstrate the feasibility of stereovision-mediated coregistration of a human spinal surgical field using a proof-of-principle study, and to provide preliminary assessments of the technique's accuracy.MethodsA total of 9 subjects undergoing image-guided pedicle screw placement also underwent stereovision-mediated coregistration with preoperative CT imaging. Stereoscopic images were acquired using a tracked, calibrated stereoscopic camera system mounted on an operating microscope. Images were processed, reconstructed, and segmented in a semi-automated manner. A multistart registration of the reconstructed spinal surface with preoperative CT was performed. Registration accuracy, measured as surface-to-surface distance error, was compared between stereovision registration and a standard registration.ResultsThe mean surface reconstruction error of the stereovision-acquired surface was 2.20 ± 0.89 mm. Intraoperative coregistration with stereovision was performed with a mean error of 1.48 ± 0.35 mm compared to 2.03 ± 0.28 mm using a standard point-based registration method. The average computational time for registration with stereovision was 95 ± 46 s (range 33-184 s) vs 10to 20 min for standard point-based registration.ConclusionSemi-automated registration of a spinal surgical field using stereovision is possible with accuracy that is at least comparable to current landmark-based techniques.Copyright © 2017 by the Congress of Neurological Surgeons

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…