    A pocket-sized metabolic analyzer for assessment of resting energy expenditure.

    • Di Zhao, Xiaojun Xian, Mirna Terrera, Ranganath Krishnan, Dylan Miller, Devon Bridgeman, Kevin Tao, Lihua Zhang, Francis Tsow, Erica S Forzani, and Nongjian Tao.
    • Center for Bioelectronics and Biosensors, The Biodesign Institute, Arizona State University, United States; School for Engineering of Matter, Transport, and Energy, Arizona State University, United States.
    • Clin Nutr. 2014 Apr 1; 33 (2): 341-7.

    Background & AimsThe assessment of metabolic parameters related to energy expenditure has a proven value for weight management; however these measurements remain too difficult and costly for monitoring individuals at home. The objective of this study is to evaluate the accuracy of a new pocket-sized metabolic analyzer device for assessing energy expenditure at rest (REE) and during sedentary activities (EE). The new device performs indirect calorimetry by measuring an individual's oxygen consumption (VO2) and carbon dioxide production (VCO2) rates, which allows the determination of resting- and sedentary activity-related energy expenditure.MethodsVO2 and VCO2 values of 17 volunteer adult subjects were measured during resting and sedentary activities in order to compare the metabolic analyzer with the Douglas bag method. The Douglas bag method is considered the Gold Standard method for indirect calorimetry. Metabolic parameters of VO2, VCO2, and energy expenditure were compared using linear regression analysis, paired t-tests, and Bland-Altman plots.ResultsLinear regression analysis of measured VO2 and VCO2 values, as well as calculated energy expenditure assessed with the new analyzer and Douglas bag method, had the following linear regression parameters (linear regression slope LRS0, and R-squared coefficient, r(2)) with p = 0: LRS0 (SD) = 1.00 (0.01), r(2) = 0.9933 for VO2; LRS0 (SD) = 1.00 (0.01), r(2) = 0.9929 for VCO2; and LRS0 (SD) = 1.00 (0.01), r(2) = 0.9942 for energy expenditure. In addition, results from paired t-tests did not show statistical significant difference between the methods with a significance level of α = 0.05 for VO2, VCO2, REE, and EE. Furthermore, the Bland-Altman plot for REE showed good agreement between methods with 100% of the results within ±2SD, which was equivalent to ≤10% error.ConclusionThe findings demonstrate that the new pocket-sized metabolic analyzer device is accurate for determining VO2, VCO2, and energy expenditure.Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…