    IntroductionPeriprosthetic fractures are difficult to manage. Plating technique has been considered a reliable form of management of periprosthetic fractures with a well-fixed stem, but a dependable and stable method of plate fixation to the bone is lacking. This study reports the clinical results using a locking attachment plate (LAP) instead of cable fixation to fix locking plates to a periprosthetic femoral shaft fracture.Materials And MethodsNineteen patients with periprosthetic femoral shaft fractures around well-fixed stemmed implants were studied between August 2012 and December 2014. Patients were followed up for at least 1 year postoperatively. Median age was 74 years (range 56-96 years). Fractures were classified according to the Unified Classification System, Vancouver classification, and Su classification.ProcedureOpen reduction was performed under minimal incision and the locking plate was fixed to the lateral cortex of the femoral shaft. The part of the shaft without a stem was fixed to the plate using 5.0-mm locking screws, and the part with an underlying stem was fixed using 3.5-mm locking screws through the LAP instead of cables. Postoperatively, patients were managed using general principles for femoral shaft fractures.ResultsAverage follow-up was 16 months (range 12-36 months). All cases achieved fracture healing without loss of reduction. There were no cases of implant breakage or stem loosening at final follow-up. The average number of LAPs per fixation construct was 2.1 (range 1-4), and the average number of 3.5-mm locking screws through each LAP was 3.3 (range 2-4). The average value of plate screw density was 0.55 (range 0.37-0.8), and the average working length was four holes (range 2-8).ConclusionsUsing the LAP to manage periprosthetic fractures with a well-fixed stem could obviate the need for cable around the stem area and yield acceptable outcomes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.