• Injury · Aug 2017

    Percutaneous screw fixation of the iliosacral joint: A case-based preoperative planning approach reduces operating time and radiation exposure.

    • T M Ecker, J Jost, J L Cullmann, W D Zech, V Djonov, Keel M J B MJB Department of Orthopaedic and Trauma Surgery, University of Bern, Inselspital, Freiburgstrasse 3, 3010 Bern, Switzerland., L M Benneker, and J D Bastian.
    • Department of Orthopaedic and Trauma Surgery, University of Bern, Inselspital, Freiburgstrasse 3, 3010 Bern, Switzerland.
    • Injury. 2017 Aug 1; 48 (8): 1825-1830.

    IntroductionA preoperative planning approach for percutaneous screw fixation of the iliosacral joint provides specific entry points (EPs) and aiming points (APs) of intraosseous screw pathways (as defined by CT scans) for lateral fluoroscopic projections used intraoperatively. The potential to achieve the recommended EPs and APs, to obtain an ideal screw position (perpendicular to the iliosacral joint), to avoid occurrence of extraosseous screw misplacement, to reduce the operating time and the radiation exposure by utilizing this planning approach have not been described yet.MethodsOn preoperative CT scans of eight human cadaveric specimen individual EPs and APs were identified and transferred to the lateral fluoroscopic projection using a coordinate system with the zero-point in the center of the posterior cortex of the S1 vertebral body (x-axis parallel to upper S1 endplate). Distances were expressed in relation to the anteroposterior distance of the S1 upper endplate (in%). In each specimen on one side a screw was placed with provided EP and AP (New Technique) whereas at the contralateral side a screw was placed without given EP and AP (Conventional Technique). Both techniques were compared using postoperative CT scans to assess distances between predefined EPs and APs and the actually obtained EPs and APs, screw angulations in relation to the iliosacral joint in coronal and axial planes and the occurrence of any extraosseous screw misplacement. The "operating time (OT)" and the "time under fluoroscopy (TUF)" were recorded. Statistical analysis was performed by the Wilcoxon signed-rank test.ResultsEPs were realized significantly more accurate using the new technique in vertical direction. The screw positions in relation to the iliosacral joint showed no significant difference between both techniques. Both techniques had one aberrantly placed screw outside the safe corridor. The (mean±SD) "OT" and the (mean±SD) "TUF" were significantly decreased using the new technique compared to the conventional technique (OT: 7.6±2min versus 13.1±5.8min, p=0.012; TUF: 1.5±0.8min versus 2.2±1.1min).ConclusionThe presented preoperative planning approach increases the accuracy in percutaneous screw fixation of the iliosacral joint, reduces operating time and minimizes radiation exposure to patient and staff.Copyright © 2017. Published by Elsevier Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.