• Lancet · Aug 2017

    Review Meta Analysis

    2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy.

    • Ziad A Ali, Patrick W Serruys, Takeshi Kimura, Runlin Gao, Stephen G Ellis, Dean J Kereiakes, Yoshinobu Onuma, Charles Simonton, Zhen Zhang, and Gregg W Stone.
    • New York Presbyterian Hospital, Columbia University Medical Center and the Cardiovascular Research Foundation, New York, NY, USA.
    • Lancet. 2017 Aug 19; 390 (10096): 760-772.

    BackgroundBioresorbable vascular scaffolds (BVS) offer the potential to improve long-term outcomes of percutaneous coronary intervention after their complete bioresorption. Randomised trials have shown non-inferiority between BVS and metallic drug-eluting stents at 1 year in composite safety and effectiveness outcomes, although some increases in rates of target vessel-related myocardial infarction and device thrombosis were identified. Outcomes of BVS following the first year after implantation are unknown. We sought to ascertain whether BVS are as safe and effective as drug-eluting stents within 2 years after implantation and between 1 and 2 years.MethodsWe did a systematic review and meta-analysis of randomised trials in which patients were randomly assigned to everolimus-eluting Absorb BVS or metallic everolimus-eluting stents (EES) and followed up for at least 2 years. We searched MEDLINE, the Cochrane database, TCTMD, ClinicalTrials.gov, Clinical Trial Results, CardioSource, and abstracts and presentations from major cardiovascular meetings up to April 1, 2017, to identify relevant studies. The primary efficacy outcome measure was the device-oriented composite endpoint (cardiac mortality, target vessel-related myocardial infarction, or ischaemia-driven target lesion revascularisation) and the primary safety outcome measure was definite or probable device thrombosis. Individual patient data from the four ABSORB trials were used for landmark and subgroup analysis and multivariable modelling.FindingsWe identified seven randomised trials in which 5583 patients were randomly assigned to Absorb BVS (n=3261) or metallic EES (n=2322) and followed up for 2 years. BVS had higher 2-year relative risks of the device-oriented composite endpoint than did EES (9·4% [304 of 3217] vs 7·4% [169 of 2299]; relative risk [RR] 1·29 [95% CI 1·08-1·56], p=0·0059). These differences were driven by increased rates of target vessel-related myocardial infarction (5·8% [187 of 3218] vs 3·2% [74 of 2299]; RR 1·68 [95% CI 1·29-2·19], p=0·0003) and ischaemia-driven target lesion revascularisation (5·3% [169 of 3217] vs 3·9% [90 of 2300]; 1·40 [1·09-1·80], p=0·0090) with BVS, with non-significant differences in cardiac mortality. The cumulative 2-year incidence of device thrombosis was higher with BVS than with EES (2·3% [73 of 3187] vs 0·7% [16 of 2281]; RR 3·35 [95% CI 1·96-5·72], p<0·0001). Landmark analysis between 1 and 2 years also showed higher rates of the device-oriented composite endpoint (3·3% [69 of 2100] vs 1·9% [23 of 1193]; RR 1·64 [95% CI 1·03-2·61], p=0·0376) and device thrombosis (0·5% [11 of 2085] vs none [0 of 1183], p<0·0001) in BVS-treated patients than in EES-treated patients.InterpretationBVS was associated with increased rates of composite device-oriented adverse events and device thrombosis cumulatively at 2 years and between 1 and 2 years of follow-up compared with EES.FundingAbbott Vascular.Copyright © 2017 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.