• World Neurosurg · Oct 2017

    Finite Element Analysis of Influence of Axial Position of Center of Rotation of a Cervical Total Disc Replacement on Biomechanical Parameters: Simulated Two-Level Replacement Based on a Validated Model.

    • Yang Li, Zhenjun Zhang, Zhenhua Liao, Zhongjun Mo, and Weiqiang Liu.
    • Department of Mechanical Engineering, Tsinghua University, Beijing, China.
    • World Neurosurg. 2017 Oct 1; 106: 932-938.

    BackgroundFinite element models have been widely used to predict biomechanical parameters of the cervical spine. Previous studies investigated the influence of position of rotational centers of prostheses on cervical biomechanical parameters after 1-level total disc replacement. The purpose of this study was to explore the effects of axial position of rotational centers of prostheses on cervical biomechanics after 2-level total disc replacement.MethodsA validated finite element model of C3-C7 segments and 2 prostheses, including the rotational center located at the superior endplate (SE) and inferior endplate (IE), was developed. Four total disc replacement models were used: 1) IE inserted at C4-C5 disc space and IE inserted at C5-C6 disc space (IE-IE), 2) IE-SE, 3) SE-IE, and 4) SE-SE. All models were subjected to displacement control combined with a 50 N follower load to simulate flexion and extension motions in the sagittal plane. For each case, biomechanical parameters, including predicted moments, range of rotation at each level, facet joint stress, and von Mises stress on the ultra-high-molecular-weight polyethylene core of the prostheses, were calculated.ResultsThe SE-IE model resulted in significantly lower stress at the cartilage level during extension and at the ultra-high-molecular-weight polyethylene cores when compared with the SE-SE construct and did not generate hypermotion at the C4-C5 level compared with the IE-SE and IE-IE constructs.ConclusionsBased on the present analysis, the SE-IE construct is recommended for treating cervical disease at the C4-C6 level. This study may provide a useful model to inform clinical operations.Copyright © 2017 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…