    Measurement Error of a Simplified Protocol for Quantitative Sensory Tests in Chronic Pain Patients.

    • Monika Müller, Biurrun Manresa José Alberto JA, Andreas Limacher, Konrad Streitberger, Peter Jüni, Ole Kæseler Andersen, and Michele Curatolo.
    • From the *Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, Bern; †Institute of Social and Preventive Medicine, University of Bern, Bern, Switzerland; ‡Center for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark; §Clinical Trials Unit Bern, Department of Clinical Research, University of Bern, Bern, Switzerland; ∥Applied Health Research Centre (AHRC) Li Ka Shing Knowledge Institute of St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada; and **Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, WA.
    • Reg Anesth Pain Med. 2017 Sep 1; 42 (5): 660-668.

    Background And ObjectivesLarge-scale application of Quantitative Sensory Tests (QST) is impaired by lacking standardized testing protocols. One unclear methodological aspect is the number of records needed to minimize measurement error. Traditionally, measurements are repeated 3 to 5 times, and their mean value is considered. When transferring QST to a clinical setting, reducing the number of records would be desirable to meet the time constraints encountered in a routine clinical environment and to reduce the testing burden to chronic pain patients. However, there might be a trade-off between measurement error and number of records. We determined the measurement error of a single versus the mean of 3 records of pressure pain detection threshold (PPDT), electrical pain detection threshold (EPDT), and nociceptive withdrawal reflex threshold (NWRT) in 429 chronic pain patients recruited in a routine clinical setting.MethodsWe calculated intraclass correlation coefficients and performed a Bland-Altman analysis.ResultsIntraclass correlation coefficients were all clearly greater than 0.75, and Bland-Altman analysis showed minute systematic errors with small point estimates and narrow 95% confidence intervals. Reducing the number of records from traditionally 3 to only 1 did not lead to relevant measurement error in PPDT, EPDT, or NWRT.ConclusionsThis study contributes to a standardized QST protocol, and based on the minimal measurement error of 1 single record of PPDT, EPDT, and NWRT, we submit to reduce the testing burden. This would allow saving time, resources, and patient discomfort.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…