    End-Expiratory Occlusion Test Predicts Fluid Responsiveness in Patients With Protective Ventilation in the Operating Room.

    • Matthieu Biais, Mathilde Larghi, Jeremy Henriot, Hugues de Courson, Musa Sesay, and Karine Nouette-Gaulain.
    • Anesth. Analg. 2017 Dec 1; 125 (6): 1889-1895.

    BackgroundEnd-expiratory occlusion test (EEOT) has been proposed to predict fluid responsiveness in mechanically ventilated intensive care unit patients. The utility of this test during low-tidal-volume ventilation remains uncertain. This study aimed to determine whether hemodynamic variations induced by EEOT could predict the effect of volume expansion in patients with protective ventilation in the operating room.MethodsForty-one patients undergoing neurosurgery were included. Stroke volume and pulse pressure variations were continuously recorded using pulse contour analysis before and immediately after a 30-second EEOT and after volume expansion (250 mL saline 0.9% given over 10 minutes). Patients with an increase in stroke volume ≥ 10% after volume expansion were defined as responders.ResultsTwenty patients were responders to fluid administration. EEOT induced a significant increase in stroke volume, which was correlated with the stroke volume changes induced by volume expansion (r = 0.55, P < .0001). A 5% increase in stroke volume during EEOT discriminated responders to volume expansion with a sensitivity of 100% (95% confidence interval [CI], 83%-100%), a specificity of 81% (95% CI, 58%-95%), a positive predictive value of 84% (95% CI, 64%-96%), and a negative predictive value of 100% (95% CI, 80%-100%). The gray zone ranged from 4% to 8%, including 17% of patients. The best pulse pressure variation threshold was 9%, with a sensitivity of 60% (95% CI, 36%-81%) and specificity of 86% (95% CI, 64%-97%). The area under the receiver operating characteristics curve generated for changes in stroke volume induced by EEOT (0.91, 95% CI, 0.81-1.00) was significantly higher than the one obtained for pulse pressure variations (0.75, 95% CI, 0.60-0.90); P < .05.ConclusionsChanges in stroke volume index induced by EEOT can predict fluid responsiveness in patients with protective ventilation in the operating room. This test may have potential applications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…