• Anesthesia and analgesia · Oct 2017

    Multicenter Study Observational Study

    Alarm Limits for Intraoperative Drug Infusions: A Report From the Multicenter Perioperative Outcomes Group.

    • Mitchell F Berman, Nikhil Iyer, Leon Freudzon, Shuang Wang, Robert E Freundlich, Michelle Housey, Sachin Kheterpal, and Multicenter Perioperative Outcomes Group (MPOG) Perioperative Clinical Research Committee.
    • From the *Department of Anesthesiology, Columbia University Medical Center, New York, New York; †Department of Anesthesiology, University of Michigan Medical School, Ann Arbor, Michigan; ‡Department of Anesthesiology, Yale University School of Medicine, New Haven, Connecticut; §Department of Biostatistics, Mailman School of Public Health, Columbia University, New York, New York; and ‖Department of Anesthesiology, Vanderbilt University Medical Center, Nashville, Tennessee.
    • Anesth. Analg. 2017 Oct 1; 125 (4): 1203-1211.

    BackgroundContinuous medication infusions are commonly used during surgical procedures. Alarm settings for infusion pumps are considered important for patient safety, but limits are not created in a standardized manner from actual usage data. We estimated 90th and 95th percentile infusion rates from a national database for potential use as upper limit alarm settings.MethodsWe extracted infusion rate data from 17 major hospitals using intraoperative records provided by Multicenter Perioperative Outcomes Group for adult surgery between 2008 and 2014. Seven infusions were selected for study: propofol, remifentanil, dexmedetomidine, norepinephrine, phenylephrine, nitroglycerin, and esmolol. Each dosage entry for an infusion during a procedure was included. We estimated the 50th, 90th, and 95th percentile levels for each infusion across institutions, and performed quantile regression to examine factors that might affect the percentiles rates, such as use in general anesthesia versus sedation.ResultsThe median 90th and 95th percentile infusion rates (with interquartile range) for propofol were 150 (140-150) and 170 (150-200) μg/kg/min. Quantile regression demonstrated higher 90th and 95th percentile rates during sedation for gastrointestinal endoscopy than for all surgical procedures performed under general anesthesia. For selected vasoactive medications, the corresponding median 90th and 95th percentile rates (with interquartile range) were norepinephrine 14.0 (9.8-18.1) and 18.3 (12.6-23.9) μg/min, and phenylephrine 60 (55-80) and 80 (75-100) μg/min.ConclusionsAlarm settings based on infusion rate percentile limits would be triggered at predictable rates; ie, the 95th percentile would be exceeded and an alarm sounded during 1 in 20 infusion rate entries. As a result, institutions could establish pump alarm settings consistent with desired alarm frequency using their own or externally validated usage data. Further study will be needed to determine the optimal percentile for infusion alarm settings.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…