-
- Raphael van Tulder, Dominik Roth, Roberta Laggner, Mario Krammel, Christoph Schriefl, Calvin Kienbacher, Heinz Novosad, Constantin Christof Chwojka, Fritz Sterz, Christof Havel, Wolfgang Schreiber, and Harald Herkner.
- Department of Emergency Medicine, Medical University of Vienna, Austria.
- Emergencias. 2017 Feb 1; 29 (1): 11-17.
ObjectivesThe quality of telephone-assisted cardiopulmonary resuscitation (CPR) needs improvement. This study investigates whether a dispatchers' perception is an adequate measure of the actual quality of CPR provided by laypersons.Material And MethodsIndividual participant data from 3 randomized simulation trials, with identical methodology but different interventions, were combined for this analysis. Professional dispatchers gave telephone assistance to laypersons, who each provided 10 minutes of CPR on a manikin. Dispatchers were requested to classify the quality of providers' CPR as adequate or inadequate. Based on actual readings from manikins we classified providers' performance as adequate at 5-6 cm for depth and 100-120 compressions per minute (cpm) for rate. We calculated metrics of dispatcher accuracy.ResultsSix dispatchers rated the performance of 94 laypersons (38 women [42%]) with a mean (SD) age of 37 (14) years. In 905 analyzed minutes of telephone-assisted CPR, the mean compression depth and rate was 41 (13) mm and 98 (24) cpm, respectively. Analysis of dispatchers' diagnostic test accuracy for adequate compression depth yielded a sensitivity of 65% (95 CI 36%-95%) and specificity of 42% (95% CI, 32%-53%). Analysis of their assessment of adequate compression rate yielded a sensitivity of 75% (95% CI, 64%-86%) and specificity of 42% (95% CI, 32%-52%). Although dispatchers always underestimated the actual values of CPR parameters, the female dispatchers evaluations were less inaccurate than the evaluations of make dispatchers; the dispatchers overall (males and females together) underestimated the adequacy of female laypersons' CPR performance to a greater degree than female dispatchers did.ConclusionThe ability of dispatchers to estimate the quality of telephone-assisted CPR is limited. Dispatchers estimates of CPR adequacy needs to be studied further in order to find ways that telephone-assisted CPR might be improved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.