    Predicting Extubation Outcome by Cough Peak Flow Measured Using a Built-in Ventilator Flow Meter.

    • Florent Gobert, Hodane Yonis, Romain Tapponnier, Raul Fernandez, Marie-Aude Labaune, Jean-François Burle, Jack Barbier, Bernard Vincent, Maria Cleyet, Jean-Christophe Richard, and Claude Guérin.
    • Hospices Civils de Lyon, Hôpital de la Croix Rousse, Service de Réanimation Médicale, Lyon, France. gobert.flo@gmail.com.
    • Respir Care. 2017 Dec 1; 62 (12): 1505-1519.

    BackgroundSuccessful weaning from mechanical ventilation depends on the patient's ability to cough efficiently. Cough peak flow (CPF) could predict extubation success using a dedicated flow meter but required patient disconnection. We aimed to predict extubation outcome using an overall model, including cough performance assessed by a ventilator flow meter.MethodsThis was a prospective observational study conducted from November 2014 to October 2015. Before and after a spontaneous breathing trial, subjects were encouraged to cough as strongly as possible before freezing the ventilator screen to assess CPF and tidal volume (VT) in the preceding inspiration. Early extubation success rate was defined as the proportion of subjects not re-intubated 48 h after extubation. Diagnostic performance of CPF and VT was assessed by using the area under the curve of the receiver operating characteristic curve. Cut-off values for CPF and VT were defined according to median values and used to describe the performance of a predictive test combining them with risk factors of early extubation failure.ResultsAmong 673 subjects admitted, 92 had a cough assessment before extubation. For the 81 subjects with early extubation success, the median CPF was -67.7 L/min, and median VT was 0.646 L. For the 11 subjects with early extubation failure, the median CPF was -57.3 L/min, and median VT was 0.448 L. Area under the curve was 0.61 (95% CI 0.37-0.83) for CPF and 0.64 (95% CI 0.42-0.84) for CPF/VT combined. After dichotomization (CPF < -60 L/min or VT > 0.55 L), there was a synergistic effect to predict early extubation success (P < .001). The predictive value of success reached 94.2% for CPF/VT combined. The overall model including pH before extubation < 7.45 reached a 66.7% predictive value of failure.ConclusionsCPF measured using the flow meter of an ICU ventilator was able to predict extubation success and to build a composite score to predict extubation failure. The results were close to that found in previous studies that used a dedicated flow meter. This could help to identify high-risk subjects to prevent extubation failure. (ClinicalTrials.gov registration NCT02847221.).Copyright © 2017 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.