• Masui · Jun 1995

    Clinical Trial Controlled Clinical Trial

    [Tele-ECG transmission for patients with out-of-hospital cardiac arrest in Osaka City].

    • M Shindoh, S Nishi, S Kurita, M Hayashi, H Yukioka, and M Fujimori.
    • Department of Emergency Medicine, Osaka City University Hospital.
    • Masui. 1995 Jun 1; 44 (6): 890-4.

    AbstractThe efficacy of a tele-ECG transmission system for transmission of electrocardiograms from ambulance to Osaka City University Hospital for 59 patients with out-of-hospital cardiac arrest was evaluated from December 1992 to November 1993. Authorized emergency life saving technicians (ELSTs) transmitted electrocardiograms by automobilephone connected with electrocardiogram from the location of out-of-hospital cardiac arrest recognized by them to the ICU. Successful tele-ECG transfer was achieved in 34 cases (57.6%). The most common reason for failure of transmission was interference by large buildings located in our urban location, which occurred in 12 of the 25 cases. Defibrillary shock was applied in 9 of 10 cases of ventricular fibrillation, and one patient among them could return to work. In most cases, laryngeal mask airway insertion was performed. The group with tele-ECG transmission required longer time for transfer to the hospital. The time required for insertion of the laryngeal mask airway and tele-ECG transmission appeared to be the main reason for the delay in transport. Although use of tele-ECG transmission can be useful for patients with out-of-hospital cardiac arrest, further improvement on the transmission system will be needed.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…