• Annals of surgery · Jun 1997

    Ventricular assist devices as a bridge to cardiac transplantation. A prelude to destination therapy.

    • W L Holman, R C Bourge, R D Spruell, C P Murrah, D C McGiffin, and J K Kirklin.
    • Department of Surgery, University of Alabama at Birmingham, USA.
    • Ann. Surg. 1997 Jun 1; 225 (6): 695-704; discussion 705-6.

    Objective And BackgroundVentricular assist devices (VADs) have been used for temporary circulatory support pending transplantation or recovery of the native heart. Outcome in 38 patients treated at the authors' institution with VADs pending transplantation was analyzed to provide information relevant to the future use of VADs as permanent implants.MethodsThoratec (Thoratec Laboratories, Pleasanton, CA) or HeartMate (Thermo Cardiosystems, Woburn, MA) VADs were used in all cases. Patients were considered for VAD placement if they were candidates for cardiac transplantation and fulfilled the criteria for the Food and Drug Administration investigational Device Exemption trials. The following adverse events were included in the analysis; death during VAD support, device malfunction, bleeding, neurologic events, support-related events that preclude transplantation, and device-related infections. Patient survival and complication rates were quantified using the Kaplan-Meier method, competing risk analysis, and hazard functions.ResultsNineteen patients had transplantation. Three patients had VAD removal after cardiac recovery and 16 died without transplantation. The duration of VAD support ranged from 0 to 279 days. The hazard function for death during VAD support had an early phase that lasted for 2 weeks after VAD placement, and early death was related to the preimplant condition of the patient. Device-related infections were noted in 11 patients. Seven of these patients had transplantation after clearing the infection, whereas four died without transplantation. Neurologic events occurred in seven patients. There were no device malfunctions that led to patient death.ConclusionsThe absence of fatal device malfunctions suggests that longer term support with current VAD designs is feasible. Appropriate patient selection, infection control, and avoidance of thromboembolic neurologic complications will be crucial to the success of permanent VAD use.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…