J Clin Monit Comput · Aug 2018
Comparative StudyA novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.
- Sándor Földi, Tamás Horváth, Flóra Zieger, Péter Sótonyi, and György Cserey.
- Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungary. foldi.sandor@itk.ppke.hu.
- J Clin Monit Comput. 2018 Aug 1; 32 (4): 717-727.
AbstractThe accurate, non-invasive, measuring of the continuous arterial blood pressure waveform faces some difficulties and an innovative blood pressure measurement technology is urgently needed. However, the arterial blood pressure waveform plays an essential role in health care by providing diagnostic information and base for calculating several heart function parameters. The aim of this study is to introduce a novel non-invasive measuring system that can measure the arterial blood pressure waveform with high accuracy in comparison to an applanation tonometry system. The applied measuring device utilizes a new measurement strategy enabled by the OptoForce 3D force sensor, which is attached to the wrist at the radial artery. To validate the accuracy, 30 simultaneous measurements were taken with a Millar tonometer. For the simultaneously recorded non-invasive signals, the similarity was high (the average correlation was [Formula: see text]). The differences in the systolic and the diastolic blood pressure measured by the two systems are small. The average differences ([Formula: see text]) for simultaneously recorded systolic, diastolic, mean arterial and incisura pressures were: [Formula: see text], [Formula: see text], [Formula: see text] and [Formula: see text], respectively. These results satisfy the AAMI criteria. Based on our results, this new system requires further development and validation against invasive arterial blood pressure monitoring in order to prove its usefulness in patient monitoring, emergency care, and pulse diagnosis.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.