-
J. Cardiovasc. Electrophysiol. · Dec 2014
Randomized Controlled Trial Multicenter StudyRationale and Design of FIRE AND ICE: A multicenter randomized trial comparing efficacy and safety of pulmonary vein isolation using a cryoballoon versus radiofrequency ablation with 3D-reconstruction.
- Alexander Fürnkranz, Josep Brugada, Jean-Paul Albenque, Claudio Tondo, Kurt Bestehorn, Karl Wegscheider, Feifan Ouyang, and Karl-Heinz Kuck.
- Cardioangiologisches Centrum Bethanien, Wilhelm Epstein Strasse, Frankfurt, Germany.
- J. Cardiovasc. Electrophysiol. 2014 Dec 1; 25 (12): 1314-20.
BackgroundAtrial fibrillation (AF) is the most common sustained cardiac arrhythmia imposing substantial morbidity and mortality. Catheter-based pulmonary vein isolation (PVI) using radiofrequency current (RFC) has become a standard treatment for drug-resistant and symptomatic paroxysmal AF (PAF). In recent years, the cryoballoon-based technique is increasingly used as a promising alternative with a short learning curve.MethodsThe FIRE AND ICE trial is a prospective, randomized, controlled, open, blinded outcome assessment, noninferiority trial comparing cryoballoon-, and RFC-based PVI. Patients with drug-resistant PAF will be randomized in a 1:1 matrix in multiple European centers. The primary hypothesis is that cryoballoon ablation is not inferior to RFC ablation using 3-dimensional mapping with respect to clinical efficacy. The primary endpoint is defined as the time to first documented clinical failure, including: (1) recurrence of AF; (2) atrial flutter or atrial tachycardia; (3) prescription of class I or III antiarrhythmic drugs; or (4) re-ablation, whichever comes first, following a blanking period of 3 months after the index ablation procedure. The primary safety endpoint is a composite of death, stroke/transient ischemic attack, cardiac arrhythmias (apart from AF recurrence) causally related to the therapeutic intervention, and procedure-related serious adverse events.ConclusionThe FIRE AND ICE trial compares 2 different technologies to perform catheter ablation of PAF with respect to efficacy and safety. It aims at providing objective data to guide selection and usage of ablation catheters in the treatment of AF.© 2014 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.