• J Neurosurg Spine · Oct 2016

    Prevention of neurological complications using a neural monitoring system with a finger electrode in the extreme lateral interbody fusion approach.

    • Wataru Narita, Ryota Takatori, Yuji Arai, Masateru Nagae, Hitoshi Tonomura, Tatsuro Hayashida, Taku Ogura, Hiroyoshi Fujiwara, and Toshikazu Kubo.
    • Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine; and.
    • J Neurosurg Spine. 2016 Oct 1; 25 (4): 456-463.

    AbstractOBJECTIVE Extreme lateral interbody fusion (XLIF) is a minimally disruptive surgical procedure that uses a lateral approach. There is, however, concern about the development of neurological complications when this approach is used, particularly at the L4-5 level. The authors performed a prospective study of the effects of a new neural monitoring system using a finger electrode to prevent neurological complications in patients treated with XLIF and compared the results to results obtained in historical controls. METHODS The study group comprised 36 patients (12 male and 24 female) who underwent XLIF for lumbar spine degenerative spondylolisthesis or lumbar spine degenerative scoliosis at L4-5 or a lower level. Using preoperative axial MR images obtained at the mid-height of the disc at the treated level, we calculated the psoas position value (PP%) by dividing the distance from the posterior border of the vertebral disc to the posterior border of the psoas major muscle by the anteroposterior diameter of the vertebral disc. During the operation, the psoas major muscle was dissected using an index finger fitted with a finger electrode, and threshold values of the dilator were recorded before and after dissection. Eighteen cases in which patients had undergone the same procedure for the same indications but without use of the finger electrode served as historical controls. Baseline clinical and demographic characteristics, PP values, clinical results, and neurological complications were compared between the 2 groups. RESULTS The mean PP% values in the control and finger electrode groups were 17.5% and 20.1%, respectively (no significant difference). However, 6 patients in the finger electrode group had a rising psoas sign with PP% values of 50% or higher. The mean threshold value before dissection in the finger electrode group was 13.1 ± 5.9 mA, and this was significantly increased to 19.0 ± 1.5 mA after dissection (p < 0.001). A strong negative correlation was found between PP% and threshold values before dissection, but there was no correlation with threshold values after dissection. The thresholds after dissection improved to 11 mA or higher in all patients. There were no serious neurological complications in any patient, but there was a significantly lower incidence of transient neurological symptoms in the finger electrode group (7 [38%] of 18 cases vs 5 [14%] of 36 cases, p = 0.047). CONCLUSIONS The new neural monitoring system using a finger electrode may be useful to prevent XLIF-induced neurological complications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…