• Der Unfallchirurg · Jun 2018

    [Analysis of the accuracy of fit of five anatomically precontoured clavicle plate systems].

    • Johannes Oppermann, Linda Ettmann, Carolin Meyer, Christian Ries, Gregor Stein, Christian Karl Spies, Lars Peter Müller, and Christoph Faymonville.
    • Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Köln (AöR), Universität zu Köln, Kerpener Straße 62, 50937, Köln, Deutschland. johannes.oppermann@uk-koeln.de.
    • Unfallchirurg. 2018 Jun 1; 121 (6): 475-482.

    BackgroundA common method in surgical treatment of midshaft clavicular fractures is the clavicle plating system. In addition to traditional osteosynthetic devices, anatomically preformed plate systems also exist. Advantages are described in greater accuracy of fit and less irritation of surrounding soft tissues. The purpose of this study was to compare the anatomical fit of five different precontoured clavicle plating systems.Material And MethodsThe anatomical fit of five different types of anatomical precontoured clavicle plates, 3 times VariaxSystem® (Stryker, Kalamazoo, MI), Meves® Plate (Ulrich medical Ulm, Germany) and LCP clavicle plate (Synthes, Bettlach, Switzerland) were investigated in 20 embalmed human cadaveric clavicles. An imprint of the space between the well-positioned plate and the clavicle was obtained using a silicone mass and the silicone imprint was digitally measured. Additionally, the anatomical fit was evaluated by three investigators following a standardized protocol (+2 to -2 points at lateral, midshaft and medial clavicle portions).ResultsThe first three ranks went to the Stryker Variax-plates. They showed the least distance (Stryker 628027: 7‑hole 1.44 mm, low curvature 0.93 mm-2.36 mm, 2. Stryker 628028: 8‑hole low curvature 1.68 mm, 1.03 mm-2.4 mm and 3. Stryker 628128: 8‑hole high curvature 1.87 mm, range 1.09 mm-3.1 mm) The evaluation of the anatomical fit by the investigators was in agreement with the measurement results.ConclusionAlthough there was no complete congruency between the plates and the clavicle, all clavicle plates investigated in this study presented a reasonable anatomical shape. The 7‑hole VariAx Stryker plate with slight curvature showed the best anatomical fit. A low profile and optimized anatomical precontouring can minimize irritation of the surrounding soft tissues and should be considered in plate design and implant choice.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…