• J. Cardiothorac. Vasc. Anesth. · Feb 2018

    Accuracy of a Simulation Algorithm for Modelling LV Contractility, Diastolic Capacitance, and Energetics Using Data Available From Common Hemodynamic Monitors and Echocardiography.

    • Paul M Heerdt, Scott Korfhagen, Hesham Ezz, and Clara Oromendia.
    • Department of Anesthesiology, Division of Applied Hemodynamics, Yale School of Medicine, New Haven, CT. Electronic address: paul.heerdt@yale.edu.
    • J. Cardiothorac. Vasc. Anesth. 2018 Feb 1; 32 (1): 381-388.

    ObjectiveTo test the hypothesis that a simulation algorithm populated with data readily available from hemodynamic monitors and echocardiography can accurately model cardiac contractility, diastolic capacitance, and energetics.DesignBland-Altman analysis of paired data sets.SettingUniversity laboratory.ParticipantsArchived data previously recorded from 7 anesthetized swine.Measurements And Main ResultsLeft ventricular pressure and volume (LVV) data that had been continuously recorded over a range of inotropic conditions were used as reference data. One investigator performed conventional analysis of measured pressure/volume loops during preload reduction to derive reference values for end-systolic elastance (Ees-a measure of contractility), the predicted LVV at an end-diastolic pressure of 30 mmHg (V30-an index of diastolic capacitance and chamber dilation), and pressure-volume area (PVA-a correlate of myocardial oxygen consumption). Other investigators blinded to these results entered pressure, cardiac output, and ejection fraction measurements into a simulator that predicts Ees, V30, and PVA. Analysis of simulated data was performed before and after correction of the estimated LVV at which pressure would be 0 mmHg (V0), which was initially fixed in the model. Before V0 correction, accuracy and precision of Ees, V30, and PVA tended to fall outside predefined limits for method interchangeability, but utility for qualitative assessment of acute changes was evident. After V0 correction, the accuracy and precision of simulated data were within the defined limits for method interchangeability.ConclusionsThese data support the potential for clinical utility of simulation models populated with data readily available at the bedside to characterize left ventricular mechanical performance and energetics.Copyright © 2018 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.