-
J Bone Joint Surg Am · Aug 2011
Pyrolytic carbon resurfacing arthroplasty for osteoarthritis of the proximal interphalangeal joint of the finger.
- Thomas M Sweets and Peter J Stern.
- Department of Orthopedic Surgery, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267-0212, USA.
- J Bone Joint Surg Am. 2011 Aug 3; 93 (15): 1417-25.
BackgroundPyrolytic carbon resurfacing arthroplasty of the proximal interphalangeal joint has been reported to provide favorable results. The purpose of this study was to evaluate the effectiveness of pyrolytic carbon joint replacement at an average follow-up of fifty-five months.MethodsA retrospective review of thirty-one arthroplasties of the proximal interphalangeal joint performed by a single surgeon in seventeen patients with interphalangeal joint osteoarthritis was conducted. Assessment included range of motion, patient satisfaction, and pain scores. Radiographs were evaluated for alignment, implant subsidence, and implant failure. The Michigan Hand Outcomes Questionnaire was administered at the time of the final follow-up.ResultsThe average follow-up period was fifty-five months (minimum, two years). No patient was lost to follow-up. The arc of motion of the interphalangeal joint decreased from 57° preoperatively to 31° (p < 0.05) at the time of the final follow-up. The average score for pain was 3 of 10 on a visual analog scale. Satisfaction averaged 3.4 points on a 5-point Likert scale, and twelve of seventeen patients stated that they would repeat the surgery. Data from the Michigan Hand Outcomes Questionnaire were compared for the involved and noninvolved hands of the fifteen patients who received implants unilaterally. Significant deficits were observed in the total outcome score, activities of daily living, function, and satisfaction for the operatively treated hand. Pain was also greater in the operatively treated hand. Complications included implant fracture (one joint), dislocation (five joints), squeaking (eleven), loosening (fifteen), and interphalangeal joint contracture (twenty). Six joints required a reoperation (an arthrodesis in four joints, a silicone arthroplasty in one, and excision of exostosis in one). Implant migration was severe for seven proximal phalanx implants and three distal phalanx implants, and one implant breached the phalangeal cortex.ConclusionsInterphalangeal joint motion decreased significantly at the final follow-up evaluation, following short-term gains in the initial postoperative period. Complications were numerous, and implant loosening with migration was a major problem. Arthroplasty of the proximal interphalangeal joint with a pyrolytic carbon implant has a high complication rate, poor outcomes, and variable patient satisfaction. On the basis of these findings, we no longer use this implant in our practice.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.