Observational Study
Single centre observational study to evaluate the safety and efficacy of the Proceed™ Ventral Patch to repair small ventral hernias.
- J Bontinck, I Kyle-Leinhase, P Pletinckx, V Vergucht, R Beckers, and F Muysoms.
- Department of Surgery, AZ Maria Middelares, Kortrijksesteenweg 1026, Ghent, 9000, Belgium.
- Hernia. 2014 Oct 1; 18 (5): 671-80.
BackgroundThere is evidence that mesh repair for primary umbilical hernias results in less recurrences and similar wound complication rates compared to tissue repair. In recent years, several mesh devices for the repair of small ventral hernias have been developed, but some reports have been published on serious complications and adverse effects encountered with those mesh devices.MethodsThe Proceed™ Ventral Patch (PVP™) is a partially absorbable lightweight polypropylene mesh. We introduced PVP™ in our department in April 2009 and collected patient data and outcome in an observational study of 101 consecutive patients until December 2011 (Clinical.Trials.gov: NCT01307696). In addition to the routine control 3 weeks postoperative, prospective follow-up included a questionnaire, clinical investigation and ultrasound after 12 months.ResultsThe study included 91 primary (76 umbilical/15 epigastric) and 10 incisional ventral hernias (including 6 trocar hernias). In all patients a PVP™ with a diameter of 6.4 cm was used. Wound problems were the most frequent complication (n = 18). Follow-up of at least 12 months was achieved in 98 patients (97 %) and the mean follow-up time was 15.9 months. Follow-up by clinical examination diagnosed a recurrence in 11/92 patients (12.0 %). Only four patients were aware of their recurrent hernia, the seven others reported no problems in the questionnaire. The additional ultrasound performed did not reveal recurrences that were not already diagnosed by clinical examination. In five patients a reoperation for repair of the recurrence was performed (reoperation rate 5/98 = 5.1 %). Hernia defect size (p = 0.032) and type of hernia (p = 0.029) were found to be a significant risk factors for development of a recurrent hernia (Fisher's exact test). Hernia size was a significant risk factor both in a univariate (p = 0.005) and in a multivariate Cox model (p = 0.017). Incisional hernia was of borderline significance in a univariate (p = 0.047) and in a multivariate Cox model (p = 0.08).ConclusionIntensive clinical follow-up yields a high percentage (12.0 %) of clinically proven, but often asymptomatic recurrences after repair of small ventral hernias with the PVP™. Reoperation rate for recurrence was 5.1 %. Hernia defect size is a significant risk factor for recurrence. Therefore, we recommend using the PVP™ only for primary ventral hernias smaller than 2 cm. For larger or incisional hernias other techniques allowing the use of larger meshes is advocated.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.