Arch Orthop Trauma Surg · Apr 2018
Biomechanical performance of the Actifit® scaffold is significantly improved by selection of irrigation fluid.
- Arnd Hoburg, Philipp von Roth, Shimon Roy-Ali, Jan-Erik Ode, Dag Wulsten, Tobias M Jung, and Clemens Gwinner.
- Center for Musculoskeletal Surgery, Charité, Universitaetsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany. arnd.hoburg@charite.de.
- Arch Orthop Trauma Surg. 2018 Apr 1; 138 (4): 537-542.
PurposeClinical reports on meniscal scaffolds seem promising, albeit relatively paucity exists regarding their biomechanical behavior. The aim of the study is to delineate the impact of differing suture materials and the type as well as the temperature of the irrigation fluid on the pull-out strength of a polyurethane meniscal scaffold (Actifit®).Materials And Methods128 specimens were utilized with horizontal sutures and uniaxial load-to-failure testing was performed. We compared two different suture materials-polydioxanone (PDS) and non-absorbable, braided polyester sutures (NABP)-as well as two common irrigation fluids-lactated Ringer's and electrolyte-free, hypotonic Mannitol-Sorbitol. All specimens were further evaluated according to two different temperatures [room temperature (20 °C) and near-core body temperature (37 °C)].ResultsMean load-to-failure was 53.3 ± 6.5 N. There was no significant difference between the NABP and the PDS group. Ringer group showed a significantly higher load-to-failure compared to Purisole (P = .0002). This was equivalent for both PDS (P = .0008) and NABP sutures (P = .0008). Significantly higher failure loads could be established for the 37° group (P = .041); yet, this difference was neither confirmed for the PDS or in in the NABP subgroup. Only the subgroup using Purisole at 37° showed significantly higher failure loads compared to 20° (P = .017).ConclusionsThis study underlines the potential to improve pull-out strength during implantation of an Actifit® scaffold by alteration of the type of irrigation fluid. Lactated Ringer solution provided the highest construct stability in regard to load-to-failure testing and should be considered whenever implantation of a polyurethane meniscal scaffold is conducted.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.