Catheter Cardiovasc Interv · Feb 2017
Clinical TrialTriGuard™ HDH embolic deflection device for cerebral protection during transcatheter aortic valve replacement.
- Mariam Samim, Bart van der Worp, Pierfrancesco Agostoni, Jeroen Hendrikse, Ricardo P J Budde, Freek Nijhoff, Faiz Ramjankhan, Pieter A Doevendans, and Pieter R Stella.
- Department of Cardiology, University Medical Centre Utrecht, the Netherlands.
- Catheter Cardiovasc Interv. 2017 Feb 15; 89 (3): 470-477.
ObjectivesThis study aims to evaluate the safety and performance of the new embolic deflection device TriGuard™HDH in patients undergoing TAVR.BackgroundTranscatheter aortic valve replacement (TAVR) is associated with a high incidence of new cerebral ischemic lesions. The use of an embolic protection device may reduce the frequency of TAVR-related embolic events.MethodsThis prospective, single arm feasibility pilot study included 14 patients with severe symptomatic aortic stenosis scheduled for TAVR. Cerebral diffusion weighted magnetic resonance imaging (DWI) was planned in all patients one day before and at day 4 (±2) after the procedure. Major adverse cerebral and cardiac events (MACCEs) were recorded for all patients. Primary endpoints of this study were I) device performance success defined as coverage of the aortic arch takeoffs throughout the entire TAVR procedure and II) MACCE occurrence. Secondary endpoints included the number and the volume of new cerebral ischemic lesions on DWI.ResultsThirteen patients underwent transfemoral TAVR and one patient a transapical procedure. Edwards SAPIEN valve prosthesis was implanted in 8 (57%) patients and Medtronic CoreValve prosthesis in the remaining 6 (43%). Predefined performance success of the TriGuard™HDH device was achieved in 9 (64%) patients. The composite endpoint MACCE occurred in none of the patients. Post-procedural DWI was performed in 11 patients. Comparing the DWI of these patients to a historical control group showed no reduction in number [median 5.5 vs. 5.0, P = 0.857], however there was a significant reduction in mean lesion volume per patient [median 13.8 vs. 25.1, P = 0.049].ConclusionThis study showed the feasibility and safety of using the TriGuard™HDH for cerebral protection during TAVR. This device did not decrease the number of post-procedural new cerebral DWI lesions, however its use showed decreased lesion volume as compared to unprotected TAVR. © 2016 Wiley Periodicals, Inc.© 2016 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.