• J. Thorac. Cardiovasc. Surg. · Jun 2018

    Midterm outcomes after aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium.

    • Shigeyuki Ozaki, Isamu Kawase, Hiromasa Yamashita, Shin Uchida, Mikio Takatoh, and Nagaki Kiyohara.
    • Department of Cardiovascular Surgery, Toho University Ohashi Medical Center, Tokyo, Japan. Electronic address: ozakis@oha.toho-u.ac.jp.
    • J. Thorac. Cardiovasc. Surg. 2018 Jun 1; 155 (6): 2379-2387.

    ObjectiveWe had previously reported the short-term results of the aortic valve neocuspidization (AVNeo) procedure. We have now evaluated the midterm results with the longest follow-up of 118 months.MethodsFrom April 2007 through December 2015, 850 patients were treated with AVNeo using autologous pericardium. Medical records of these patients were retrospectively reviewed. The procedure was on the basis of independent tricuspid replacement using autologous pericardium. The distances between the commissures were measured with an original sizing device, the pericardial cusp was trimmed using an original template, and then sutured to the annulus.ResultsThere were 534 patients with aortic stenosis, 254 with aortic regurgitation, 61 with aortic stenoregurgitation, 19 with infective endocarditis, and 5 with a previous aortic valve procedure. Besides 596 patients with tricuspid aortic valve, 224 patients had bicuspid valve, 28 had unicuspid valve, and 2 had quadricuspid valve. There were 444 male and 406 female patients. The median age was 71 (range, 13-90) years old. Preoperative echocardiography revealed a peak pressure gradient average of 68.9 ± 36.3 mm Hg with aortic stenosis. Surgical annular diameter was 20.9 ± 3.3 mm. There was no conversion to a prosthetic valve replacement. There were 16 in-hospital mortalities. Postoperative echocardiography revealed a peak pressure gradient average of 19.5 ± 10.3 mm Hg 1 week after surgery and 15.2 ± 6.3 mm Hg 8 years after surgery. Fifteen patients needed reoperation (13 infective endocarditis, 1 break of thread, and 1 tear of cusp case). The mean follow-up period was 53.7 ± 28.2 months. Actuarial freedom from death, cumulative incidence of reoperation, and that of recurrent moderate aortic regurgitation or greater was 85.9%, 4.2%, and 7.3%, respectively, with the longest follow-up of 118 months.ConclusionsThe midterm outcomes of AVNeo using autologous pericardium were satisfactory in 850 patients with various aortic valve diseases. However, further randomized, multicenter prospective studies are needed to confirm the results of the current study.Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…