Observational StudyNon-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting.
- Tammo A Brouwer, Charina van den Boogaard, Eric N van Roon, Cor J Kalkman, and Nic Veeger.
- Department of Anaesthesiology, Medical Center Leeuwarden, Henri Dunantweg 2, PO Box 888, 8901 BR, Leeuwarden, The Netherlands. t.brouwer@znb.nl.
- J Clin Monit Comput. 2018 Dec 1; 32 (6): 1117-1126.
AbstractUltrasound scanning of bladder volume is used for prevention of postoperative urinary retention (POUR). Accurate assessment of bladder volume is needed to allow clinical decision-making regarding the need for postoperative catheterization. Two commonly used ultrasound devices, the BladderScan® BVI 9400 and the newly released Prime® (Verathon Medical®, Bothell, WA, USA), with or without the 'pre-scan' option, have not been validated in clinical practice. The aim of this study was to assess the performance of these devices in daily clinical practice. Between June and September 2016 a prospective observational study was conducted in 318 surgical patients (18 years or older) who needed a urinary catheter perioperatively for clinical reasons. For acceptable performance, we required that the volume as estimated by the BladderScan® differs by no more than 5% from the actual urine volume after catheterization. The Schuirmann's two one-sided test was performed to assess equivalence between the BladderScan® estimate and catheterization. The BVI 9400® overestimated the actual bladder volume by + 17.5% (95% CI + 8.8 to + 26.3%). The Prime® without pre-scan underestimated by - 4.1% (95% CI - 8.8 to + 0.5%) and the Prime® with pre-scan underestimated by - 6.3% (95% CI - 11.6 to - 1.1%). This study shows that while both ultrasound devices were able to approximate current bladder volume, both BVI 9400® and Prime®-with and without pre-scan-were not able to measure the actual bladder volume within our predefined limit of ± 5%. Using the pre-scan feature of the Prime® did not further improve accuracy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.