    Study DesignTo determine the effect of cage/spacer stiffness on the stresses in the bone graft and cage subsidence.ObjectiveTo investigate the effect of cage stiffness on the biomechanics of the fused segment in the lumbar region using finite element analysis.Summary Of Background DataThere are a wide variety of cage/spacer designs available for lumbar interbody fusion surgery. These range from circular, tapered, rectangular with and without curvature, and were initially manufactured using titanium alloy. Recent advances in the medical implant industry have resulted in using medical grade polyetheretherketone (PEEK). The biomechanical advantages of using different cage material in terms of stability, subsidence, and stresses in bone graft are not fully understood.MethodsA previously validated 3-dimensional, nonlinear finite element model of an intact L3-L5 segment was modified to simulate posterior interbody fusion spacers made of PEEK ("E" = 3.6 GPa) and titanium ("E" = 110 GPa) at the L4/5 disc with posterior instrumentation. Bone graft ("E" = 12 GPa) packed between the spacers in the intervertebral space was also simulated. The posterior lumbar interbody fusion spacer with instrumentation and graft represent a simulation of the condition present immediately after surgery.ResultsThe peak centroidal Von Mises stresses in the graft bone increased by at least 9-fold with PEEK spacers as compared to titanium spacer. The peak centroidal Von Mises stresses in the endplates increased by at least 2.4-fold with titanium spacers over the PEEK spacers. These stresses were concentrated at places where the spacer interfaced with the endplate. The stiffness of the spacer did not affect the relative motion (stability) across the instrumented (L4/5) segment.ConclusionsSpacers less stiff than the graft will: (1) provide stability similar to titanium cages in the presence of posterior instrumentation, (2) reduce the stresses in endplates adjacent to the spacers, and (3) increase the load transfer through the graft, as evident from the increase in stresses in graft.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…