- Rania M Sarhan, Ahmed A Elberry, Nada Saed Abdelwahab, Hoda Rabea, Mohamed Nabil Salem, and Mohamed Ea Abdelrahim.
- Clinical Pharmacy Department, Faculty of Pharmacy, Beni-suef University, Beni-suef, Egypt.
- Respir Care. 2018 Sep 1; 63 (9): 1125-1131.
BackgroundA new holding chamber was designed to be used with the Aerogen Solo nebulizer to increase the aerosol emitted that reach the patient. The aim of this study was to evaluate the efficacy of this holding chamber with the nebulizer and determine its usability with other nebulizers.MethodsThe study was divided into 2 parts. In the first part, aerosol emitted of 1 mL respirable solution (nominal dose of 5000 μg salbutamol), delivered by using the mesh nebulizer, Pro nebulizer, and jet nebulizer, connected to a T-piece or a holding chamber, was determined by using a breathing simulator set to provide a tidal volume of 500 mL, frequency of 15 breaths/min, and the inspiratory-expiratory ratio of 1:1 for adults as the quiet breathing pattern. Aerodynamic particle size characterizations were determined by using a cooled cascade impactor at an inhalation flow of 15 L/min. In the second part of the study, 12 healthy nonsmoking subjects (6 females) >18 y, with an FEV1 > 90% were enrolled. Inhaled aerosol of 1 mL respirable solution (5,000 μg salbutamol) was delivered through the mesh nebulizer-holding chamber and an mesh nebulizer-T-piece using normal tidal breathing. The subjects provided urine samples 30 min after dosing and cumulatively collected their urine for 24 h. The samples were analyzed for salbutamol content.ResultsThe holding chamber significantly increased aerosol emitted by the 3 nebulizers compared with the T-piece (P < .01) and relatively decreased the mass median aerodynamic diameter but with no significant difference. The mesh nebulizer-holding chamber resulted in significantly higher aerosol emitted compared with any other delivery method tested (P < .01). The mesh nebulizer-holding chamber resulted in higher urine samples 30 min after dosing (as an index of lung deposition) and cumulatively collected urine for 24 h (as an index of systemic absorption) compared with the nebulizer-T-piece (P < .05).ConclusionsThe use of the holding chamber with a jet nebulizer, Pro nebulizer, and the Solo nebulizer significantly increased the aerosol delivery. The Solo nebulizer-holding chamber had the highest aerosol emitted compared with all nebulizer-adapter combinations and higher urine samples 30 min after dosing and cumulatively collected urine for 24 h compared with the nebulizer-T-piece.Copyright © 2018 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.