• J Laparoendosc Adv Surg Tech A · Aug 2009

    Risk of ventriculoperitoneal shunt infections after laparoscopic placement of Chait Trapdoor cecostomy catheters in children.

    • Sani Z Yamout, Betty J Huo, Veetai Li, Mauricio A Escobar, and Michael G Caty.
    • Department of Pediatric Surgery, Women and Children's Hospital of Buffalo, 219 Bryant Street, Buffalo, NY 14222, USA. syamout@kaleidahealth.org
    • J Laparoendosc Adv Surg Tech A. 2009 Aug 1; 19 (4): 571-3.

    IntroductionLaparoscopic placement of Chait Trapdoor (Cook, Bloomington, IN) cecosotomy catheters has been practiced in our institution since 1999. Chait cecostomy catheters allow antegrade irrigation of the colon without the complications associated with appendicostomies. Although the use of laparoscopy allows precise placement of these catheters into the cecum under direct vision, the presence of a concomitant ventriculoperitoneal (VP) shunt raises concerns for the potential for a shunt infection.Materials And MethodsThis is a retrospective review of all patients with VP shunts who underwent laparoscopic placement of a Chait cecostomy catheter from 1999 to 2008. We recorded patient demographics, indication for VP shunt placement, the date of the most recent shunt operation, the method of cecal fixation, follow-up duration, and episodes of shunt infection.ResultsSixteen patients with spina bifida and VP shunts who underwent laparoscopic placement of a Chait cecostomy catheter were identified. There were 12 males. Mean follow-up was 46 +/- 27 months (range, 3-87). Two patients (12.5%) developed a VP shunt infection related to the placement of their cecostomy catheter. One shunt infection occurred 5 days postoperatively and the other occurred several years later, when the shunt and cecostomy catheter tracts merged in the subcutaneous tissue. Both patients underwent shunt externalization.ConclusionsCecostomy catheter placement in patients with preexisting VP shunts may increase the risk of shunt infections. Our series illustrates two different mechanisms by which a VP shunt can become infected after this procedure. In the first case, leakage of enteric content from a poorly sealed tract probably resulted in the shunt infection. More secure fixation of the cecum to the abdominal wall, using intracorporeal sutures rather than T-fasteners, may avoid this complication. The second complication could have been avoided if the cecostomy catheter had been placed further away from the VP shunt.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.