Randomized Controlled Trial
Transnasal humidified rapid insufflation ventilatory exchange for oxygenation of children during apnoea: a prospective randomised controlled trial.
- T Riva, T H Pedersen, S Seiler, N Kasper, L Theiler, R Greif, and M Kleine-Brueggeney.
- Department of Anaesthesiology & Pain Therapy, Bern University Hospital, Inselspital, Freiburgstrasse 8, 3010 Bern, Switzerland.
- Br J Anaesth. 2018 Mar 1; 120 (3): 592-599.
BackgroundTransnasal humidified rapid insufflation ventilatory exchange (THRIVE) comprises the administration of heated, humidified, and blended air/oxygen mixtures via nasal cannula at rates of ≥2 litres kg-1 min-1. The aim of this randomized controlled study was to evaluate the length of the safe apnoea time using THRIVE with two different oxygen concentrations (100% vs 30% oxygen) compared with standard low-flow 100% oxygen administration.MethodsSixty patients, aged 1-6 yr, weighing 10-20 kg, undergoing general anaesthesia for elective surgery, were randomly allocated to receive one of the following oxygen administration methods during apnoea: 1) low-flow 100% oxygen at 0.2 litres kg-1 min-1; 2) THRIVE 100% oxygen at 2 litres kg-1 min-1; and 3) THRIVE 30% oxygen at 2 litres kg-1 min-1. Primary outcome was time to desaturation to 95%. Termination criteria included SpO2 decreased to 95%, transcutaneous CO2 increased to 65 mmHg, or apnoea time of 10 min.ResultsThe median (interquartile range) [range] apnoea time was 6.9 (5.7-7.8) [2.8-10.0] min for low-flow 100% oxygen, 7.6 (6.2-9.1) [5.2-10.0] min for THRIVE 100% oxygen, and 3.0 (2.4-3.7) [0.2-5.3] min for THRIVE 30% oxygen. No significant difference was detected between apnoea times with low-flow and THRIVE 100% oxygen administration (P=0.15). THRIVE with 30% oxygen demonstrated significantly shorter apnoea times (P<0.001) than both 100% oxygen modalities. The overall rate of transcutaneous CO2 increase was 0.57 (0.49-0.63) [0.29-8.92] kPa min-1 without differences between the 3 groups (P=0.25).ConclusionsHigh-flow 100% oxygen (2 litres kg-1 min-1) administered via nasal cannulas did not extend the safe apnoea time for children weighing 10-20 kg compared with low-flow nasal cannula oxygen (0.2 litres kg-1 min-1). No ventilatory effect was observed with THRIVE at 2.0 litres kg-1 min-1.Clinical Trial RegistrationNCT02979067.Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.