-
- Pietro Scarone, Gabriele Vincenzo, Daniela Distefano, Filippo Del Grande, Alessandro Cianfoni, Stefano Presilla, and Michael Reinert.
- 1Neurosurgical Service, Neurocenter of Southern Switzerland, and.
- J Neurosurg Spine. 2018 Oct 1; 29 (4): 397-406.
ObjectiveNavigation-enabling technology such as 3D-platform (O-arm) or intraoperative mobile CT (iCT-Airo) systems for use in spinal surgery has considerably improved accuracy over that of traditional fluoroscopy-guided techniques during pedicular screw positioning. In this study, the authors compared 2 intraoperative imaging systems with navigation, available in their neurosurgical unit, in terms of the accuracy they provided for transpedicular screw fixation in the thoracic and lumbar spine.MethodsThe authors performed a retrospective analysis of clinical and surgical data of 263 consecutive patients who underwent thoracic and lumbar spine screw placement in the same center. Data on 97 patients who underwent surgery with iCT-Airo navigation (iCT-Airo group) and 166 with O-arm navigation (O-arm group) were analyzed. Most patients underwent surgery for a degenerative or traumatic condition that involved thoracic and lumbar pedicle screw fixation using an open or percutaneous technique. The primary endpoint was the proportion of patients with at least 1 screw not correctly positioned according to the last intraoperative image. Secondary endpoints were the proportion of screws that were repositioned during surgery, the proportion of patients with a postoperative complication related to screw malposition, surgical time, and radiation exposure. A blinded radiologist graded screw positions in the last intraoperative image according to the Heary classification (grade 1-3 screws were considered correctly placed).ResultsA total of 1361 screws placed in 97 patients in the iCT-Airo group (503 screws) and in 166 in the O-arm group (858 screws) were graded. Of those screws, 3 (0.6%) in the iCT-Airo group and 4 (0.5%) in the O-arm group were misplaced. No statistically significant difference in final accuracy between these 2 groups or in the subpopulation of patients who underwent percutaneous surgery was found. Three patients in the iCT-Airo group (3.1%, 95% CI 0%-6.9%) and 3 in the O-arm group (1.8%, 95% CI 0%-4.0%) had a misplaced screw (Heary grade 4 or 5). Seven (1.4%) screws in the iCT-Airo group and 37 (4.3%) in the O-arm group were repositioned intraoperatively (p = 0.003). One patient in the iCT-Airo group and 2 in the O-arm group experienced postoperative neurological deficits related to hardware malposition. The mean surgical times in both groups were similar (276 [iCT-Airo] and 279 [O-arm] minutes). The mean exposure to radiation in the iCT-Airo group was significantly lower than that in the O-arm group (15.82 vs 19.12 mSv, respectively; p = 0.02).ConclusionsIntroduction of a mobile CT scanner reduced the rate of screw repositioning, which enhanced patient safety and diminished radiation exposure for patients, but it did not improve overall accuracy compared to that of a mobile 3D platform.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.