• Prehosp Emerg Care · Jan 2019

    A Novel Infant Chest Compression Assist Device Using a Palm Rather Than Fingers: A Randomized Crossover Trial.

    • Joong Wan Park, Jae Yun Jung, Joonghee Kim, Young Ho Kwak, Kim Do Kyun DK, Jung Chan Lee, Eun Mi Ham, Soyun Hwang, and Hyuksool Kwon.
    • Prehosp Emerg Care. 2019 Jan 1; 23 (1): 74-82.

    AbstractObjective: We developed a novel compression assist device (palm presser) to perform chest compressions using a palm in infant cardiopulmonary resuscitation (CPR). We hypothesized that the palm presser will increase compression depth without increasing hands-off time and will reduce rescuer fatigue compared with the two-finger technique (TFT).Methods: In this randomized crossover manikin trial, participants performed two minutes of CPR with a 30:2 compression:ventilation ratio using the palm presser and the TFT in randomized sequence on an infant manikin. CPR parameters, including compression depth and hands-off time, were collected to compare CPR quality between the palm presser and the TFT. The linear mixed-effect model was used to control the carryover effect of a crossover design in the analysis of CPR parameters. To evaluate rescuer fatigue, we compared changes in compression depth over time and calculated the odds of sufficiently deep compressions over time between the two groups.Results: The palm presser resulted in greater mean compression depth (41.5 ± 1.6 mm vs. 36.8 ± 5.5 mm, p < 0.001), greater sufficiently deep compressions (80.9 ± 27.8% vs. 42.4 ± 35.4%, p < 0.001), and better correct hand position (99.9 ± 0.5% vs. 83.9 ± 25.3%, p = 0.013) than the TFT. Total compressions, compression rate, total ventilations, volume of ventilations, and hands-off time were not significantly different between the two groups. The mean change in compression depth over time was greater with the TFT than with the palm presser (regression coefficient: -0.024 [95% CI -0.030 to -0.018] vs. -0.004 [95% CI -0.006 to -0.002]). The odds of a compression depth greater than 40 mm increased 2.8 times (95% CI 2.2 to 3.4) with the TFT during the first minute compared with the last minute, whereas the corresponding odds ratio when using the palm presser was not significantly different in the first and last minutes (OR: 1.2 [95% CI 0.9 to 1.5]).Conclusions: Compression with palm pressers resulted in greater compression depth without increasing hands-off time and reduced rescuer fatigue compared with compression with the TFT in simulated infant CPR with manikins.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.