-
- David N Ranney, Judson B Williams, Andrew Wang, and Jeffrey G Gaca.
- Division of Cardiovascular and Thoracic Surgery, Department of Surgery, Duke University Medical Center, Durham, North Carolina.
- J Card Surg. 2016 May 1; 31 (5): 282-8.
BackgroundTranscatheter valve-in-valve (VIV) procedures are an alternative to standard surgical valve replacement in high risk patients.MethodsCases in which a commercially approved transcatheter aortic valve replacement (TAVR) device was used for a nonaortic VIV procedure between November 2013 and September 2015 are reviewed. Clinical, echocardiographic, and procedural details, patient survival, and symptom severity by NYHA class at follow-up were assessed.ResultsAll patients were heart-team determined high risk for conventional redo surgery (mean STS PROM = 6.8 ± 2.2%). Five patients underwent VIV replacement in the nonaortic position, four for bioprosthetic mitral valve dysfunction, and one for bioprosthetic tricuspid valve dysfunction. Bioprosthetic failure was due to stenosis in three patients and regurgitation in two others. A balloon-expandable device was used for all patients (Edwards Lifesciences, Irvine, CA, USA). Transcatheter VIV replacement was accomplished by the transapical (mitral) and transfemoral venous (tricuspid) approaches. Median postoperative length of stay was five days (range 3-12). No deaths occurred at a mean follow-up of 21 months. NYHA class at follow-up decreased from class IV at baseline to class I or II for all patients. No paravalvular leaks greater than trivial were encountered. Median mean gradient following mitral replacement was 6.5 mmHg (range 6-13 mmHg), and following tricuspid replacement was 4 mmHg. Postoperative complications included hematuria, epistaxis, acute kidney injury, and atrial fibrillation.ConclusionsTranscatheter VIV implantation in the nonaortic position for dysfunctional bioprostheses can be performed safely with favorable clinical outcomes using a balloon expandable TAVR device. doi: 10.1111/jocs.12745 (J Card Surg 2016;31:282-288).© 2016 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.