• Eur J Pain · Nov 2018

    Randomized Controlled Trial Comparative Study

    Comparison of orofacial thermal sensitivity assessed with simple devices and sophisticated equipment.

    • M Ayranci, M Koutris, F Lobbezoo, P Svensson, and L Baad-Hansen.
    • Department of Oral Kinesiology, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
    • Eur J Pain. 2018 Nov 1; 22 (10): 1824-1832.

    BackgroundSimple thermal devices providing reliable data are needed to detect somatosensory disturbances in non-specialized clinical settings. Currently, evidence is lacking about their use. Therefore, the aim was to compare the assessment of perceived thermal sensitivity/pain in healthy humans with a state-of-the-art thermotester and with simple inexpensive customized thermal aluminium devices.MethodsTwenty healthy volunteers participated in the study. The infraorbital region and the tip of the tongue were tested with the Medoc Pathway thermotester and simple aluminium thermal devices, with temperatures varying between 5-50°C. A numerical rating scale (NRS) from 0-50-100 was used for rating the perceived thermal sensitivity/painfulness. A control experiment was performed with 10 of the participants to test the potential impact of temporal summation of thermal stimuli with the use of temperature ramps (Medoc) compared with static temperature (simple devices).ResultsIn the original experiment, the scores from the thermotester stimulation were higher than the scores for stimulation with the simple thermal devices with mean NRS differences between devices of 7.2 and 10.2 for the two tested regions. In the control experiment, the mean NRS differences decreased to -0.3 and 2.2, respectively.ConclusionsProvided that temporal summation of the thermal stimuli was avoided, there were only minor differences in perceived thermal sensitivity/painfulness between the two different assessment methods at both test sites. Therefore, the simple thermal devices can be useful for assessment of thermal sensitivity in clinical settings without access to expensive sophisticated equipment. However, more sophisticated equipment is needed for threshold measurements.SignificanceThis study indicates that simple thermal devices to some extent can be used in a comparable way with sophisticated thermal stimulators. Therefore, they can be useful in clinical practice, where access to further equipment is lacking.© 2018 European Pain Federation - EFIC®.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.