-
Int J Chron Obstruct Pulmon Dis · Jan 2016
Multicenter StudyIs the 1-minute sit-to-stand test a good tool for the evaluation of the impact of pulmonary rehabilitation? Determination of the minimal important difference in COPD.
- Trija Vaidya, Claire de Bisschop, Marc Beaumont, Hakima Ouksel, Véronique Jean, François Dessables, and Arnaud Chambellan.
- Explorations Fonctionnelles Respiratoires, l'institut du thorax, CHU de Nantes; Université de Poitiers, Laboratoire MOVE EA 6314, F-86000 Poitiers.
- Int J Chron Obstruct Pulmon Dis. 2016 Jan 1; 11: 2609-2616.
BackgroundThe 1-minute sit-to-stand (STS) test could be valuable to assess the level of exercise tolerance in chronic obstructive pulmonary disease (COPD). There is a need to provide the minimal important difference (MID) of this test in pulmonary rehabilitation (PR).MethodsCOPD patients undergoing the 1-minute STS test before PR were included. The test was performed at baseline and the end of PR, as well as the 6-minute walk test, and the quadriceps maximum voluntary contraction (QMVC). Home and community-based programs were conducted as recommended. Responsiveness to PR was determined by the difference in the 1-minute STS test between baseline and the end of PR. The MID was evaluated using distribution and anchor-based methods.ResultsForty-eight COPD patients were included. At baseline, the significant predictors of the number of 1-minute STS repetitions were the 6-minute walk distance (6MWD) (r=0.574; P<10-3), age (r=-0.453; P=0.001), being on long-term oxygen treatment (r=-0.454; P=0.017), and the QMVC (r=0.424; P=0.031). The multivariate analysis explained 75.8% of the variance of 1-minute STS repetitions. The improvement of the 1-minute STS repetitions at the end of PR was 3.8±4.2 (P<10-3). It was mainly correlated with the change in QMVC (r=0.572; P=0.004) and 6MWD (r=0.428; P=0.006). Using the distribution-based analysis, an MID of 1.9 (standard error of measurement method) or 3.1 (standard deviation method) was found. With the 6MWD as anchor, the receiver operating characteristic curve identified the MID for the change in 1-minute STS repetitions at 2.5 (sensibility: 80%, specificity: 60%) with area under curve of 0.716.ConclusionThe 1-minute STS test is simple and sensitive to measure the efficiency of PR. An improvement of at least three repetitions is consistent with physical benefits after PR.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.